MC9000-K/S for Embedded Windows® CE .NET Product Reference Guide
1-18
Calibration Screen 
Use calibrate screen to align the touch screen:
1.
Remove the stylus from the handle.
2.
Carefully press and briefly hold the tip of stylus on the center of the calibration screen target. 
Repeat the procedure as the target moves and stops at different locations on the screen.
3.
If the mobile computer already has screen calibration settings, the confirm calibration 
resave screen appears. Tap screen within 30 seconds to overwrite the existing calibration 
settings with the new settings or allow the timer to expire and the new calibration settings 
will not be saved. 
Figure 1-10.  Calibration Screen
Calibration Screen
Confirm Calibration Resave 