Heatcraft Refrigeration Products SWN0200H2C Manuale Utente

Pagina di 12
electrical Data
model
Power
Supply
compressor
air Defrost/
Beacon II
electric Defrost - low 
amps
electric Defrost - High 
amps
model
rla lra mca moPD
Defrost
Heater
amps*
evap.
Fan
amps mca moPD
Defrost
Heater
amps*
evap.
Fan
amps mca moPD
SWN0311L6G
230/1/60
2DF3F16KE 22.9 125.0 28.7
50
20 (1)
6
34.7
50
40 (1)
12
50.0
60
SWN0311L6C 208-230/3/60 2DF3F16KE 14.4 102.0 20.0
30
20 (1)
6
25.0
35
40 (1)
12
50.0
50
SWN0311L6D
460/3/60
2DF3F16KE
7.1
52.0 15.0
15
10 (1)
3
15.0
15
20 (1)
6
25.0
25
SWN0400L6C 208-230/3/60 2DL3F20KE 23.6 161.0 29.5
50
20 (1)
6
35.5
50
40 (1)
12
50.0
60
SWN0400L6D
460/3/60
2DL3F20KE
9.2
60.0 15.0
20
10 (1)
3
15.0
20
20 (1)
6
25.0
25
SWN0599L6C 208-230/3/60 2DA3F23KE 25.8 161.0 32.3
50
20 (1)
6
38.3
60
40 (1)
12
50.0
70
SWN0599L6D
460/3/60
2DA3F23KE 9.2
60.0 15.0
20
10 (1)
3
15.0
20
20 (1)
6
25.0
25
SWN0600L6C 208-230/3/60 2DB3F25KE 25.3 161.0 31.7
50
20 (1)
6
37.7
60
40 (1)
12
50.0
60
SWN0600L6D
460/3/60
2DB3F25KE 11.9 80.0 15.0
25
10 (1)
3
20.0
25
20 (1)
6
25.0
30
SWN0601L6C 208-230/3/60 3DA3F28KE 24.0 150.0 30.1
50
20 (1)
6
36.1
60
40 (1)
12
50.0
60
SWN0601L6D
460/3/60
3DA3F28KE 10.8 77.0 15.0
20
10 (1)
3
20.0
25
20 (1)
6
25.0
30
SWN0750L6C 208-230/3/60 3DB3F33KE 27.6 161.0 34.5
60
40 (1)
12
50.0
70
70 (2)
16
87.5
90
SWN0750L6D
460/3/60
3DB3F33KE 14.1 83.0 20.0
30
20 (1)
6
25.0
35
40 (1)
12
50.0
50
SWN0900L6C 208-230/3/60 3DF3F40KE 33.2 215.0 41.5
70
40 (1)
12
53.5
80
70 (2)
16
87.5
90
SWN0900L6D
460/3/60
3DF3F40KE 15.0 106.0 20.0
30
20 (1)
6
25.0
35
40 (1)
12
50.0
50
SWN1000L6C 208-230/3/60 SDS3F46KE 37.2 215.0 46.5
80
40 (1)
12
58.5
90
70 (2)
16
87.5
90
SWN1000L6D
460/3/60
SDS3F46KE 16.7 106.0 20.8
35
20 (1)
6
26.8
40
40 (1)
12
50.0
50
SWN1500L6C 208-230/3/60 4DL3F63KE 47.2 278.0 59.0
100
70 (2)
16
87.5
110 96 (2)
25
120.0 125
SWN1500L6D
460/3/60
4DL3F63KE 23.6 139.0 29.5
50
40 (1)
12
50.0
60
70 (2)
16
87.5
90
SWN2200L6C 208-230/3/60 4DT3F76KE 59.2 374.0 74.0
125
70 (2)
16
90.0
125 96 (2)
25
120.0 150
SWN2200L6D
460/3/60
4DT3F76KE 29.6 187.0 37.0
60
40 (1)
12
50.0
70
70 (2)
16
87.5
90
SWN model - low temperature
*Number of defrost heater contactors in parentheses
RLA - Rated Load Amps 
 
MCA - Minimum Circuit Ampacity
LRA - Locked Rotor Amps 
 
MOPD - Maximum Overcurrent Protection Device
For additional capacity sizes and options, please contact the factory at 800-1-1881