U-Line CO2175/CO2275DWR Manuale Utente

Pagina di 180
3-31
Section 3 - Service and Repair
VIEWING ACTUAL TEMPERATURE 
- 2275DWRWS ONLY
To view the temperature in the top and bottom drawer (T1 and 
T2), hold the WARMER key for five seconds until “°F” flashes. 
Release and the display will show the corrected temperatures of 
both zones on their respective displays. To view the temperature 
of T3 and T4, you must use the service mode.
VIEWING ACTUAL TEMPERATURE 
- 2275ZWC/2275ZWCOL ONLY
To display actual zone temperatures (not set-point):
1. Press and hold the WARMER icon for the desired zone for 
approximately five seconds until unit beeps, and release when 
the decimal in the display begins to flash (Figure 25).
2. The display will show the actual zone temperature.
3. After five seconds, the display will return to the set-point 
temperature.
Figure 25. Displaying Zone Temperature
CHANGING FROM FAHRENHEIT TO CELSIUS
To change the displayed temperature from °F to °C, hold the 
LIGHT key and press the down arrow three times. This will change 
all values to °C. When the key combination is accepted the control 
will beep once and change values.
SHOWROOM MODE
This mode is designed to show units in a display environment. 
When in this mode the only functions will be the control and 
cabinet lights. The compressor, fans, etc. will not operate. To enter 
this mode hold the down arrow and press the LIGHT button three 
times. When entered, the unit will beep once and the degree 
symbol will begin to flash. When the degree symbol is flashing the 
unit will allow the use of the control for demonstrations. 
On early models, after not touching the unit for one minute the 
display will begin to “snake” around. This is meant to alert you the 
unit is in showroom mode. 
On later models, the degree (°) flashes.
The unit can be left in this mode indefinitely. If you again want to 
demo the control, touch any key and the degree symbol will begin 
to flash. To exit this mode: If using software version 2.8, this mode 
will exit automatically when the unit is unplugged. If using software 
version 2.9, this mode needs to be exited by the same key 
combination as used to enter the mode.
SERVICE MODE
This mode has 27 different options available for service diagnostics. 
To enter the mode hold the WARMER key and press the LIGHT 
button three times. The display will show “0” and the board will 
beep once. When in this mode the WARMER and COLDER keys 
will act as up and down arrows to select the desired option. The 
LIGHT key is the ENTER key and will enter a function. If changing a 
function, you must press the LIGHT button again to retain the 
changed setting. To exit the service mode, scroll to option 99 and 
press the LIGHT key. After five minutes of not touching any keys 
the mode will also exit automatically.
DISPLAY TOGGLE
On glass door units the display normally stays on all the time. To 
have the display turn off with the door press the up arrow and 
touch the ON/OFF key three times. The °F sign will flash and the 
board will beep once to let you know the mode has been accepted. 
This mode can be toggled on or off by the same key combination. 
To see if the display should be staying on 100% or turning off with 
the door, you can check service option 8. Only available on  
2115WC, 2175W, 2275DWRWS, 2175BEV, 2275ZWC & 
2275ZWCOL.
BLACKOUT MODE
Hold the LIGHT key for 10 seconds until the °F starts flashing. 
When released, the unit will beep once and the display and cabinet 
light will shut off. To cancel this mode, hold the LIGHT key again 
for about 10-12 seconds.
CLEAN CYCLE
To enter the self-cleaning cycle hold the ON/OFF key and press 
the light three times. The unit will beep once and the display will 
show CL. Follow the cleaning instructions.   At the conclusion of 
this mode (1 hour) the display will revert to set-point and the unit 
will resume normal operation. To cancel this mode turn the unit 
off via the keypad. Only available on CLR2160 and 
CLRCO2175.
ICE MAKER OFF MODE
This mode will stop ice production. To enter hold the ON/OFF key 
and press the up arrow three times. The unit will beep once when 
the mode is entered. After 5-10 seconds the display will start to 
scroll from “SP” to “Ice” to “Off” as long as the mode is active. To 
exit either turn the unit off via keypad or do the same key 
combination. Only available on CO2175F, CLRCO2175 and 
CO2175DWR.
FORCED HARVEST
This mode can be used to force ice to harvest from the mold. To 
enter this mode hold LIGHT key and press the up arrow three 
times. The unit will initiate an ice harvest. There is no audible tone 
when entering this mode. Only available on CO2175F and 
CO2175DWR.
ULIN_1011_A
UPPER ZONE CONTROLS
LOWER ZONE CONTROLS
Light
Display
Power
Warmer
Warmer
Cooler
Cooler
Display