REPLACING EVAPORATOR FAN MOTOR
- CO2175DWR
1. Disconnect unit from power source.
2. Remove two screws (Figure 58) holding evaporator fan cover to 
evaporator cover.
3. Unplug fan connection.
4. Remove two nuts and two washers holding the fan to the fan 
bracket.
5. Replace with new fan.
6. Plug in the fan connection, making sure the fan wires are tucked 
behind the fan bracket.
7. Reinstall evaporator cover.
8. Reinstall unit and test.
9. Reinstall fan bracket to liner, making sure the fan wires are tucked 
behind the fan bracket.
10. Reinstall unit and test.
To access evaporator or drain:
1. Disconnect unit from power source.
2. Remove two screws (Figure 58) holding evaporator cover to 
drain pan.
3. Remove two screws holding evaporator to drain pan.
4. Remove two screws holding fan bracket to drain pan.
5. Unplug fan connection.
6. Reinstall parts in reverse order.