U-Line U-CO29B-03 Manuale Utente

Pagina di 25
u-line.com
3
Control Systems
A portion of models covered in this guide use an electronic touch 
control while others use a manual control system. See the table 
below to identify your model and equipped control system. Users 
with models using manual control should reference “Product 
Operation Manual Control” on page 6.
Air Flow
NOTICE
The unit requires proper air flow to perform at its highest 
efficiency.
Initial Startup
All U-Line controls are preset at the factory. Initial startup requires 
no adjustments. 
NOTICE
U-Line recommends allowing the unit to run overnight 
before loading refrigerator or freezer with product.
To turn the unit on or off, press and hold POWER 
 (1) for ten 
seconds and release. The display will show the unit set point 
temperature when turned on and display “OFF” when the unit is 
off. 
Electronic Control Panel
Digital Display
The electronic control with digital display shows a single 
continuous set point temperature. This set point is for the middle 
zone, it is a base number used by the controller to maintain the 
multiple temperature zones in the unit. The factory default set 
point for Beverage Center and Refrigerator models is 38°F. The set 
point temperature is a gauge for further temperature adjustments.
Adjusting Air Temperature
NOTICE
Adjust the set point temperature in single increments, 
and wait 24 hours for the temperature to stabilize before 
rechecking.
To adjust the set point temperature:
1. Press and release either WARMER 
 (2) or COOLER 
 (4) 
to put the controller in the SET TEMPERATURE mode. The 
display (3) will begin to flash the °F (or °C) symbol.
NOTE: This mode will self-cancel in five seconds, and the 
display (3) will show the original set-point temperature.
2. Within five seconds (while the °F (or °C) symbol is flashing), 
press WARMER 
 or COOLER 
 as required to adjust the 
set point temperature.
3. The change is committed 5 seconds after adjusting the 
temperature, and the display (3) will show the new set point 
temperature.
Temperature Selection (°F °C). U-Line products supplied for 
110 VAC have temperatures displayed (3) by default in Fahrenheit 
(°F). Models supplied for 220 VAC have temperatures displayed (3) 
by default in Celsius (°C).
Easily adjust the display for either type of temperature display. 
1. Press and hold LIGHT 
 (1) and simultaneously within five 
seconds press COOLER 
 (5) three times to change the 
display (3) as needed.
Temperature Display. The digital display shows set-point. Under 
normal operating conditions the temperatures will fluctuate based 
on a number of factors including door openings, product load, 
room temperature, and humidity. On passive cooled units the 
temperature will always be cool toward the top and coolest 
toward the bottom.
1. Press WARMER 
 (2) for five seconds. The display (3) will 
indicate the actual temperature.
2. After 10 seconds, the set point temperature will return to the 
display.
Product Operation Touch Control
Model
Control
Model
Control
U-CO2175FB-00
Electronic
U-CO29FB-99
Manual
U-CO2175FS-00
Electronic
U-CO29FWH-00
Manual
U-CO2175FS-01
Electronic
U-CO29WH-03
Manual
U-CO2175FW-00
Electronic
U-CO29WHTP-20
Manual
U-CO29B-00
Manual
U-C2275DWROL-00 Electronic
U-CO29B-03
Manual
U-C2275DWRS-00
Electronic
U-CO29B-20
Manual
U-2175RFB-00
Electronic
U-CO29BTP-20
Manual
U-2175RFS-00
Electronic
U-CO29FB-00
Manual
U-2175RFS-01
Electronic
U-CO29FB-98
Manual
U-2175RFW-00
Electronic
1
2
3
5
4