U-Line 2175BEV Manuale Utente

Pagina di 180
3-62
Section 3 - Service and Repair
Figure 70
3. Your U-Line icemaker requires a drain connection. This unit can be 
purchased with or without a factory-installed drain pump. If a 
pump is not installed in the appliance you must use the 
gravity drain style installation
 OR install a pump per the 
installation instructions found on www.U-Line.com.  
4. Slide two hose clamps onto the drain connection on the rear of the 
appliance. Insert the barbed fitting half-way into this connection. 
On the other end of the barbed fitting attach the 5/8" braided 
tubing. Slide a clamp onto each side of the barbed fitting as shown 
(Figure 71 & 70).
Figure 71
Figure 72
5. Determine the location of your drain and begin to route the drain 
tubing in that direction.  If using the gravity drain option you must 
provide 1/4" drop every foot of line.  For drain pump application 
you must not go higher than 10 feet of lift. The lift should be made 
vertically at the beginning of the drain line. After the lift try and 
provide 1/4" drop every foot of line to the drain location. 
6. Connect the water supply fitting by screwing the brass garden hose 
fitting to the water valve in the rear of the unit. Tighten this fitting 
with a pliers. Do not use Teflon tape or joint compound on the 
fitting. The rubber washer provides an adequate seal. Other 
materials could cause blockage of the valve. The copper water line 
should now be clamped to the rear of the unit to prevent rotation 
when sliding in. Remove the clamp from the unit, slide the tube 
into it and reattach using the 1/4" nut driver as shown (Figure 71 
and 70)
.
7. Plug in the unit and put the unit into OFF mode by holding the 
power key for 10 seconds. Not doing this will cause the unit to fill 
with water for three minutes.   
8. Turn on the water supply and ensure the connections are free of 
leaks.
9. Begin to push the appliance into the desired cabinet opening. The 
copper tubing should remain in two coils behind the unit. While 
pushing the unit into the opening continuously reroute the drain 
tube to avoid kinks. The most common installation pulls the slack 
into an adjacent cabinet or basement area. Again, if installing a 
gravity drain, ensure you provide proper slope
9/16" Wrench
1/4" Copper Water
Supply Line
7/16" Wrench
From Water Supply
to Ice Maker
ULIN_S_0168_A
ULIN_S_0166b1_A
Drain Fitting from
Back of Unit
Worm Clamps
Drain Line
5/8" x 5/8"
Barb Connector
ULIN_S_0166b2_A