Samsung ST320LM008 Manuale Utente

Pagina di 111
Spinpoint M8U-Internal Product Manual REV 3.4 
87 
INSTALLATION 
 
 
 
6.4.2.4  Endpoint Descriptor 
The device shall support at least three endpoints:  Control, Bulk-In and Bulk-Out. 
Each USB device  defines  a Control  endpoint  (Endpoint  0). This is the default  endpoint  and does not require  a 
descriptor. 
 
■  Bulk-In Endpoint 
The Bulk-In endpoint is used for transferring  data and status from the device to the host. (Table  6-24) 
 
Table 6-24: Bulk-In Endpoint  Descriptor 
 
 
 
 
 
 
■  Bulk-Out Endpoint 
The Bulk-Out  endpoint is used for transferring  command and data from the host to the device. (Table  6-25) 
 
Table 6-25: Bulk-Out  Endpoint  Descriptor 
 
 
 
 
6.4.3 Protocol (Command/Data/Status) 
Figure 6-35 - Command/Data/Status  Flow shows the flow for Command  Transport,  Data-In,  Data-Out and 
Status Transport. 
The following  sections define Command  and Status Transport. 
Figure  6-36 - Status  Transport  Flow shows  a detailed  diagram  of Status  Transport.  The following  sections 
outline the various conditions  for host/device  communication,  possible errors, and recovery procedures.