Location
Units represented in this manual are intended for indoor use 
only. Be sure the location chosen has a floor strong enough to 
support the total weight of the cabinet and contents. Reinforce 
the floor as necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good air 
circulation inside and out.
Inside cabinet: Do not pack refrigerator so full that air cannot 
circulate.
Outside cabinet: Be sure that the unit has access to ample air. On 
all 400 and 4000 Series equipment, (for 4500 Series equipment 
door  and  drawer  models  see  below),  a  minimum  space  of  3” 
(7.6cm) at the back of the unit and 1” (2.5cm) at the top and 
sides  is  required  to  conform  to  Underwriters  Laboratories’ 
standards. On undercounter units it is imperative that the proper 
air flow be maintained. The refrigeration system is designed so 
air will flow under the unit, over the compressor/condenser area, 
and out at the top rear of the unit. Avoid hot corners and locations 
near stoves and ovens.
4500 Series equipment door and drawer models: These units 
have  Delfield’s  “front-breathing”  design.  They  may  be  installed 
flush  against  a  wall  or  built  into  a  counter  as  required.  The 
louver at the floor level must be kept completely clear of any 
obstructions. Proper operation of these models is dependent on 
air being able to flow freely through the front louver. The louver 
at the back of the unit is not necessary for proper operation, but 
any air flow through is beneficial.
Any  restriction  of  the  proper  air  flow  outlined 
above, total or partial, will void the warranty on 
the unit.
Leveling
A level cabinet will perform better because the drain pan will drain 
properly, the drawers or doors will line up with the frames and the 
cabinet will not be subject to undue strain.
All four legs are adjustable. Adjust each leg until the unit is stable 
and level left to right. If necessary adjusting the front legs slightly 
higher than the rear by about 1/8” (0.3cm) will help the door or 
drawers remain closed. 
If the unit is supplied with casters, no adjustments are available.  
Ensure the floor where the unit is to be located is level.
Never stand on the unit or its drawers! Doing so may 
result in bodily injury. They are not designed to hold 
the weight of an adult and will collapse if misused in 
this manner.
Stabilizing
Some models are supplied on casters for your convenience, for 
ease of cleaning underneath and mobility.
The unit must be installed in a stable condition with 
the  front  wheels  locked.  Locking  the  front  casters 
after  installation  is  the  owner’s  and  operator’s 
responsibility.
Plumbing
Self-contained models are standard with a condensate evaporator. 
If, for some reason, a unit does not have a condensate evaporator, 
or the evaporator fails, the unit’s drain must have an outlet to an 
appropriate drainage area or container.
Moisture  collecting  from  improper  drainage  can 
create a slippery surface on the floor and a hazard 
to  employees.  It  is  the  owner’s  and  operator’s 
responsibility  to  provide  a  container  or  outlet  for 
drainage.
Electrical connection
Refer  to  the  amperage  data  on  page  3,  the  serial  tag,  your 
local code or the National Electrical Code to be sure the unit is 
connected to the proper power source. A protected circuit of the 
correct voltage and amperage must be run for connection of the 
line cord, or permanent connection to the unit.
A 7’ (2.1 m) long grounded supply cord and plug are provided 
with standard units. Simply plug the unit in to begin operation.
The thermostat must be turned to OFF and the unit 
disconnected  from  the  power  source  whenever 
performing  service,  maintenance  functions  or 
cleaning the refrigerated area.
CAUTION
Installation