GE ZDP48N6DHSS6 Manuale Utente

Pagina di 3
For answers to your Monogram,
®
 GE Profile
 or  
GE
®
 appliance questions, visit our website at  
GEAppliances.com or call GE Answer Center
®
  
service, 800.626.2000.
Listed by  
Underwriters  
Laboratories
R
Electrical Requirements
Ranges must be supplied with 208/240V, 60Hz, and connected to 
an individual, properly grounded branch circuit protected by a circuit 
breaker or time-delay fuse. Install a 50-amp circuit for 48" ranges.  
The receptacle must be a NEMA 14-50R device to accept the  
four-prong  plug on the range.
Optional Backsplash Accessories
The range requires a 12" minimum clearance to a vertical combustible 
surface at the rear. A backsplash is required for installations with  
less than 12" clearance. The following backsplash accessories are 
available, or a custom, non-combustible backsplash can be used
Backsplashes: Order one with a 48"-wide range 
ZX12B48HSS–12" backsplash
ZX22B48HSS– 22" backsplash with warming shelf
Backsplash with Warming Shelf
All Monogram Professional Wall-Mounted Hoods feature infrared 
warming lights. The 22"-high backsplash with warming shelf is  
a perfect complement when installed with the tapered or  
straight-sided hoods.
 If you choose to install this range with a Restaurant-Style  
Professional Hood (ZV48RSFSS), no additional accessories are  
required. These hoods are shipped with a stainless steel  
backsplash and warming shelf.
Side View with a Backsplash
Gas Supply
•  Natural gas models are designed to operate at 5" water column 
pressure. A regulator is required at the natural gas source to  
provide maximum of 7" water pressure to the range regulator.
•  The liquid propane models are designed to operate at 10" water 
column pressure. A regulator is required at the LP source to provide 
maximum of 14" water pressure to the range regulator.
Locate gas and  
electric as shown
8"
4"
8"
12"
16"
Gas 
Supply
48"
1-1/2"
4"
Electric
Supply
605Dia60
Backguard
36" Min. 
to 
Combustibles
0" Clearance
12" Min. to Combustibles or 
0" Min. to Combustibles
with 12" or 22" Backsplash
Specification Revised 10/05 
130550
ZDP48N6DHSS 
(Natural Gas)
 
ZDP48L6DHSS 
(Liquid Propane)
 –  GE Monogram 48" Dual Fuel Professional Range  
with 6 Burners and Griddle