Hearth & Home Technologies VRTIKL-CE Manuale Utente

Pagina di 44
9
Heat & Glo  •  VRTIKL-CE  •  7031-292 Rev E  •  12/07
V
= VENT  TERMINAL
X
= AIR SUPPLY INLET
= AREA WHERE TERMINAL IS NOT PERMITTED
     Figure 4.4  Minimum Clearances for Termination
A  
=  31 cm ....................clearances above grade, veranda, 
porch, deck or balcony
B = 
31 
cm 
....................clearances to window or door 
that may be opened, or to perma-
nently closed window. (Glass)
D* 
=  31 cm ....................vertical clearance to unventilated 
soffi t or to ventilated soffi t located 
above the terminal
 
    76 cm .....................for vinyl clad soffi ts and below 
electrical service 
=   23 cm ...................clearance to outside corner
=  15 cm ....................clearance to inside corner
=  91 cm ....................not to be installed above a gas 
meter/regulator assembly within 90 
cm horizontally from the center-line 
of the regulator
I = 
1.8 
.....................clearance to gas service regulator 
vent outlet
J = 
31 
cm 
......................clearance to non-mechanical 
air supply inlet to building or the 
combustion air inlet to any other 
gas stove
K = 
1.8 
.......................clearance to a mechanical 
(powered) air supply inlet
L** = 2.1 
.......................c l e a r a n c e   a b o v e   p a v e d 
sidewalk or a paved driveway 
located on public property
M*** =  46 cm ......................clearance under veranda, porch, 
deck, balcony or overhang
 
 
1.1 M  ......................vinyl 
  **  a fl ue shall not terminate directly above a sidewalk or paved driveway 
which is located between two single family dwellings and serves both 
dwellings.
 ***  only permitted if veranda, porch, deck or balcony is fully open on a 
minimum of 2 sides beneath the fl oor, or meets Note 2.
NOTE 1: On private property where termination is less than 7 feet above 
a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap 
shield is suggested. (See fl ue components page)
NOTE 2: Termination in an alcove space (spaces open only on one side 
and with an overhang) are permitted with the dimensions specifi ed for vinyl 
or non-vinyl siding and soffi ts.  1. There must be 2.7M minimum between 
termination caps. 2.  All mechanical air intakes within 3M  of a termination 
cap must be a minimum of 2.7M below the termination cap. 3. All gravity 
air intakes within 2.7M of a termination cap must be a minimum of .31M 
foot below the termination cap.
(See Note 1)
(See Note 1)
(See Note 2)
NOTE 3: Local codes or regulations may require different 
clearances.
NOTE 4: Termination caps may be hot. Consider their proximity to 
doors or other traffi c areas.
NOTE 5: Location of the fl ue termination must not interfere with 
access to the electrical service.
Heat & Glo assumes no responsibility for the improper performance 
of the gas stove when the fl ueing system does not meet these 
requirements.  
Q
MIN
 = # termination caps x 3        R
MAX
 = (2 / # termination caps) x Q
ACTUAL
  
Alcove  Applications 
S  =   15 cm .......................clearance from sides of elec-
trical service
T = 31 
cm 
........................clearance above electrical 
service
(See Note 5)
(See Note 5)
See Notes 3 & 4
Electrical
Service
V
S
V
S
V
T
D*
V
M
N
P
R
Q
 
    
Q
MIN 
     R
MAX
  1 cap 
 .91 M 
   2 x Q 
ACTUAL
  2 caps 
 1.8 M 
   1 x Q 
ACTUAL
  3 caps 
 2.7 M 
2/3 x Q 
ACTUAL
  4 caps 
 3.7 M 
1/2 x Q 
ACTUAL
=  15 cm  .....................non-vinyl sidewalls
 
 
31 cm  .....................vinyl sidewalls
P = 
2.4 
M