Hearth & Home Technologies MTVERNINSAE-CSB Manuale Utente

Pagina di 52
Page  2
7036-135E
September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
Hearth & Home Technologies welcomes you to our tradi-
tion of excellence!  In choosing a Quadra-Fire appliance, 
you have our assurance of commitment to quality, durabil-
ity, and performance.
This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation of 
our stoves, inserts and fireplaces.  And yet we are old-fash-
ioned when it comes to craftsmanship.  Each unit is meticu-
lously fabricated and surfaces are hand-finished for lasting 
beauty and enjoyment.  Our pledge to quality is completed 
as each model undergoes a quality control inspection.  
We wish you and your family many years of enjoyment in 
the warmth and comfort of your hearth appliance.  Thank 
you for choosing Quadra-Fire.
LABEL LOCATION: On Beaded Chain on e behind Right Side Panel
SAFETY LABEL / ÉTIQUETTE DE SÉCURITÉ
Listed Solid Fuel Room Heater/Pellet Type Insert.  Also suitable for Mobile Home 
Installation.  This appliance has been tested and listed for use in Manufactured 
Homes in accordance with OAR 814-23-9000 through 814-23-909.
R
Mt. Vernon Pellet Insert AE
Tested to: ASTM E1509-04, ULC S628, ULC/ORD-C1482-M1990 Room 
Heating Pellet Burning Type,  (UM) 84-HUD FOR USE ONLY WITH 
PELLETIZED WOOD.  SEE OWNER’S MANUAL FOR OTHER FUEL OPTIONS.
Input Rating:  60,000 BTU/HR.
Electrical Rating: 115 VAC, 60 Hz, Start 5 Amps, Run 1.25 AMPS.
Route power cord away from unit. Do not route cord under or in front of 
appliance.
DANGER:    Risk of electrical shock.  Disconnect power supply before 
servicing.
Replace glass only with 5mm ceramic available from your dealer.  
To start, set thermostat above room temperature, the stove will light 
automatically.  To shutdown, set thermostat to below room temperature.  
For further instruction refer to owner's manual.
Keep viewing and ash removal doors tightly closed during operation.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
Masonry or Zero Clearance
AS A BUILT-IN UNIT
JAN FEB  MAR  APR MAY JUNE JULY  AUG SEPT OCT NOV  DEC
7036-137
A Insert side to combustible
/ Insérez le côté au mur combustible latéral
B Insert top to face trim 
/ Insérez le dessus de la garniture de façade
C Insert side to face trim 
/ Insérez le côté de la garniture de façade
D Hearth extension from door opening 
/
 Prolongement d’âtre depuis l’ouverture de la porte devant
E Hearth extension from side of door opening 
/ Prolongement d’âtre depuis le côté
 
de l’ouverture de la porte
6 in. 
152mm
0 in.  
0mm
0 in.  
0mm
6 in.  
152mm
6 in.  
152mm
NE PAS ENLEVER L'ÉTIQUETTE
SERIAL NO. / NUMÉRO DU SÉRIE
Report / Rapport
#061-S-69-6
Made in U.S.A.
Fabriqué par
:
CAUTION
:
ATTENTION:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN 
BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.  Operate this unit with fuel hopper lid closed.  Failure to do so may 
result in emissions products’ combustion from the hopper under certain conditions.  Maintain hopper seal in 
good condition. Do not overfill hopper.
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE 
DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU.  VOIR L'ÉTIQUETTE ET LES 
INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, 
sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES: 
A  Des Conduits Du Haut/Arrières:   3 in. (76mm)
B  Des Conduits Du Haut/Arrières: 
2 in. (51mm)
C  Des Conduits Du Haut:  
 2.75 in. (70mm)
  
Arrières 
 
7.5 in. (191mm)
D  Des Conduits Arrières/Du Haut 
3 in. (76mm)
E  Côté de Fonte au Mur Latéral: 
6 in. (152mm)
Top of Hopper 
Top/Rear Vent  
3 in. (76mm)
B
Side of Outside Skin 
Top/Rear Vent 
2 in. (51mm)
Back of Hopper 
Top Vent 
7.5 in. (191mm)
 
 
Rear Vent 
2.75 in. (70mm)
D
Vent Pipe to Combustible Top/Rear Vent 
3 in. (76mm)
Cast Side to Side Wall  Top/Rear Vent 
6 in (152mm)
Testé à: ASTM #1509-04, ULC S628, ULC/ORD-C1482-M1990 Room Heating.  Pellet 
Burning Type, UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS.  VOIR LE 
MANUAL DU PROPRIÉTAIRE POUR D’AUTRES OPTIONS DE CARBURANT.
Puissance de Rendement:  60,000 BTU/HR
Puissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps, 
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous 
de l'appareil.
DANGER: Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise de contact 
avant le service.  Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible 
chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le 
poêle s'allumera automatiquement.  Pour éteindre, descendre la température du thermostat en 
dessous de la température de la pièce.  Pour des instructions supplémentaires, référez vous au 
manuel du propriétaire.  Gardez la porte d'ouverture et la porte des cendres fermées 
hermétiquement durant l'opération.
 Appareil de chauffage inséré de combustible solide/de type de boulettes.  Accepté dans 
l'installation dans les maisons mobiles.  Cet appareil a été testé et enregistré pour l'usage
dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
1445 Highway North, Colville, WA  99114
B
D
C
C
A
B
E
COMME APPAREIL INSÉRÉ
0 in. Clearance To Exposed Section and Face Trim / Espace libre 
de 0 mm de la section exposée et de la garniture du devant.
SIDE W
ALL
MANTEL
A
B
D
C
E
Face Trim
007002
2008      2008     2010
Fait Aux États-Unis
Dégagement de la maçonnerie ou Dégagement zéro*
MUR LA
TÉRAL
Garniture
de façade
MANTEAU
DO NOT REMOVE THIS LABEL
Manufactured by:
See manual for mantel clearances.
www.quadrafire.com
US
S
A
M
P
L
E
Serial Number
Model Name
Test Lab & 
Report No.
Mfg Dates