Instructions for the installer
 
 
21 
 
For operation on 380-415 V 3N
: use an H05RR-F or H05V2V2-F type 
five-core cable (5 x 1.5 mm
2
). 
 
 
 
 
 
 
For operation on 380-415 V 2N
: use an H05RR-F or H05V2V2-F type 
four-core cable (4 x 1.5 mm
2
). 
 
 
 
For operation on 220-240 V
: use an H05RR-F or H05V2V2-F type 
three-core cable (3 x 2.5 mm
2
). 
 
 
The cable end to be connected to the appliance must be provided with an 
earth wire (yellow-green) at least 20 mm longer. 
 
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions or by interference with any part of the appliance. 
 
14.4  Installation of the appliance 
 
It is the law that all gas appliances are installed by competent persons. Corgi gas installers are 
approved to work to safe and satisfactory standards. All gas installation, servicing and repair work 
must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990. 
This appliance may be installed next to a wall which is higher than the appliance as shown in the 
diagram  showing the correct installation conditions. Any wall cupboards or shelves must be at a 
distance of at least 750 m above the work surface.