Furuno 1734C Manuale Di Servizio

Pagina di 241
2. RADAR OPERATION 
 2-35
2.25.8  CPA/TCPA alarm (ARP) 
When the predicted CPA of any target becomes smaller than a preset CPA alarm range or 
its predicted TCPA less than a preset TCPA alarm limit, an audio alarm sounds and the 
speaker icon appears (in red). In addition, the target plot symbol of the offending target 
changes to a triangle and flashes together with its vector. You may silence the audio alarm 
with the CLEAR key. Press the ALARM key and the message “COLLISION ALARM” 
appears. Press the CLEAR ALARM soft key to acknowledge the alarm. The flashing of the 
triangle plot symbol continues until you intentionally terminate tracking of the target. The 
ARP continuously monitors the predicted range at the Closest Point of Approach (CPA) and 
predicted time to CPA (TCPA) of each track to own ship. 
 
This feature helps alert you to targets which may be on a collision course with own ship. 
However, it is important that gain, A/C SEA, A/C RAIN and other radar controls are properly 
adjusted and the ARP is set up so that it can track targets effectively. 
 
CPA/TCPA alarm ranges must be set up properly taking into consideration the size, 
tonnage, speed, turning performance and other characteristics of own ship. 
CAUTION
The CPA/TCPA alarm should never be
relied upon as the sole means for detect-
ing the risk of collision. The navigator is
not relieved of the responsibility to keep
visual lookout for avoiding collisions,
whether or not the radar or other plotting
aid is in use.
 
Follow the steps shown below to set the CPA/TCPA alarm 
range: 
 
1. Press the MENU key followed by the ARP SETUP soft 
key. 
2. Operate the Cursor pad to select CPA. 
3.  Press the EDIT soft key to show the CPA window. 
4.  Select a CPA limit desired from 0.5 nm, 1 nm, 2 nm, 3 
nm, 5 nm and 6 nm with the Cursor pad
5.  Press the ENTER soft key. The ARP SETUP menu 
reappears. 
6. Operate the Cursor pad to select TCPA. 
7.  Press the EDIT soft key to show the TCPA window. 
8.  Select a TCPA limit from 30 sec, 1 min, 2 min, 3 min, 4 
min, 5 min, 6 min and 12 min. 
9.  Press the ENTER soft key. 
10. Press the MENU key to close the menu. 
 
CPA
¡
¡
¡
¡
¡
¡
¤
OFF
0.5nm
1nm
2nm
3nm
5nm
6nm
 
CPA distance 
TCPA
¡
¡
¡
¡
¡
¡
¡
¤
30 seconds
1 minute
2 minutes
3 minutes
4 minutes
5 minutes
6 minutes
12 minutes
 
TCPA time