Lucent Technologies 10.21.O.X Manuale Utente
This is a guide to the information needed to install a DEFINITY ONE Communications
System. For expanded information about these topics, see
System. For expanded information about these topics, see
DEFINITY ONE
Communications System Release 2.0 Installation and Upgrades (555-233-109).
1.
Install and cable the cabinet (same as ProLogix).
2.
Power up the system (same as ProLogix).
3.
Connect the laptop computer.
4.
Access DEFINITY ONE via telnet and start a LAC bash session.
5.
Verify the serial number (use
serialnumber command). Ensure that the
serial number matches the number on the TN795 faceplate.
6.
Acquire a license file. License file information is available online. For
further information, contact your Lucent technical services
representative.
further information, contact your Lucent technical services
representative.
■
For external access: www. lucent-teamworks.com
■
For internal access: http://info.dr.lucent.com/~epr/contry
7.
Request the RAS IP address from the INADS contact person.
8.
Run
setip to set the RAS IP address, the system name; and, if
applicable, the customer LAN information.
9.
Reboot the system, using the
reboot nice command.
10. Wait for notification from INADS that the license file has been installed.
This requires a reboot.
11. Administer the DEFINITY ONE platform. For example, set the system
time and time zone, and enable customer logins. To enable AUDIX
customer logins, execute the following commands from a Bash shell:
customer logins, execute the following commands from a Bash shell:
net user sa <new password>
net user sa /active
(Repeat these commands for vm and browse logins.)
12. Administer applications (DEFINITY, AUDIX, and AUDIX Networking).
Typical Bash (GAS) commands for installation
Command
Description
alarmorig
Turns on alarm origination from the GAM (INADS)
alarmstat
Gives global alarm status (major, minor, or none) for GAM,
DEFINITY, and AUDIX
DEFINITY, and AUDIX
cleargamalarm
Clears alarms after analysis
d1stat
Displays the status of all application groups running on the
system
system
environment
Displays the TN795 temperature and voltage ranges
ftpserv
Enables the ftp service
gamalarmstat
Displays GAM alarm information
installconfig
Installs license files (INADS)
lucent help
Lists all commands
oss
Sets telephone numbers for outgoing INADS calls
pcAnywhere
Starts the pcAnywhere application (use -c to stop applica-
tion)
tion)
reboot
Reboots system as follows:
nice: shuts down applications and Windows NT in a
graceful manner
immediate: reboots the system without waiting for the
applications to shut down, causing possible loss of voice
messages that are being recorded and all calls drop
nice: shuts down applications and Windows NT in a
graceful manner
immediate: reboots the system without waiting for the
applications to shut down, causing possible loss of voice
messages that are being recorded and all calls drop
restartcause
Displays the restart causes for system (for technician/
TSC)
TSC)
setip
Sets the IP address, subnet mask, and default gateway of
the LAN interface to the customer’s LAN. Turns on RAS.
Reboot is required.
the LAN interface to the customer’s LAN. Turns on RAS.
Reboot is required.
shutdown
Shuts down:
all: Lucent DEFINITY ONE applications
system: all Lucent DEFINITY ONE applications and Win-
dows NT
appname: the name of the application to be shut down
camp-on: (AUDIX feature) notifies users of a system shut-
down all and waits for users to end their sessions before
shutting down
all: Lucent DEFINITY ONE applications
system: all Lucent DEFINITY ONE applications and Win-
dows NT
appname: the name of the application to be shut down
camp-on: (AUDIX feature) notifies users of a system shut-
down all and waits for users to end their sessions before
shutting down
serialnumber
Reads and displays the serial number of the circuit pack