Siemens S120 Manuale Utente

Pagina di 301
 
Interfaces 
 
8.3 Cooler connection 
In the case a built-in torque motor with a cooling jacket, the coolant must be 
supplied/discharged via two holes (cut by the user) in the axes construction (see following 
diagrams). For information on the installation hole fit, refer to the section titled "Installation 
drawings/Dimension drawings". 
To ensure optimized, uniform cooling across all cooling slots, the coolant infeed for torque 
motors 1FW609 and 1FW613 must be offset by 90° vis-à-vis the cable outlet for the 
electrical supply. If a different location is selected for the coolant inlet/outlet, the coolant is 
not distributed evenly in the cooling slots. The least favorable position for the coolant 
inlet/outlet is at an angle of 90° counter-clockwise because, in this case, the coolant can 
barely flow through the foremost or rearmost cooling slots. 
The coolant infeed must be positioned directly above the exit point of the electrical cable 
outlets on 1FW615 torque motors. 
 
r
&XVWRPHUKRXVLQJ
2XWJRLQJIHHGHU
SRVLWLRQ
2ULQJV
5RWRU
6WDWRU
/RFDWLQJKROH URWRU
$OOGLPHQVLRQVLQPP
,QOHW
:DWHUFRROLQJ
2XWOHW
 
Figure 8-31  Cooler connection for 1FW609 and 1FW613 (example) 
 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 
147