Install and Cable the Cabinets
Page 1-36
Install Equipment Room Hardware
1
Table 1-3.
Circuit Pack Installation Order (Loading)
Function
Apparatus Code
Load From
Notes
Processor
TN798
Slot 1 in Cabinet A
Tone Clock
TN2182B
Slot 2 in Cabinet A
Call Classifier/ Tone
Detector
Detector
TN744D
Slot 1 of Cabinet B
If slot is not available, load in
first available slot from slot 1
first available slot from slot 1
DEFINITY AUDIX
ED-1E546 (TN566/TN567)
Slots 6-9
Requires 4 slots with overlap
into area to the left of slot 6. In
any other position, 5 slots are
required.
into area to the left of slot 6. In
any other position, 5 slots are
required.
Announcement
TN750C
Lower Left
Speech Synthesizer
TN725B
Lower Left
DS1/E1, ISDN PRI
TN464F, TN767E
Lower Left
Maximum of 8 ISDN-PRI. Total
number of ISDN-PRI plus
number of ISDN-BRI circuit
packs must not exceed 8
number of ISDN-PRI plus
number of ISDN-BRI circuit
packs must not exceed 8
ISDN-BRI Trunk
TN2185
Lower Left
Maximum of 4
CO Trunk
TN747B, TN465C,
TN2199, TN2147C,
TN2138, TN438B
TN2199, TN2147C,
TN2138, TN438B
Lower Left
DID Trunk
TN753, TN2139, TN2146,
TN436B, TN459B
TN436B, TN459B
Lower Left
Tie Trunk
TN760C, TN458, TN497,
TN2140B
TN2140B
Lower Left
Auxiliary Trunk
TN763B
Lower Left
Modem Pool
TN758
Lower Left
Data Line
TN726
Upper Left
Digital Line
TN754C, TN2181,
TN2224, TN2214
TN2224, TN2214
Upper Left
Analog Line
TN746B, TN2135, TN467,
TN2144, TN2149, TN2180,
TN2183, TN2215, TN468B
TN2144, TN2149, TN2180,
TN2183, TN2215, TN468B
Upper Left
Hybrid Line
TN762B
Upper Left
MET Line
TN735
Upper Left
Radio Controller
TN789
Upper Left
ISDN-BRI 4-Wire
S/T-NT Line (A-Law)
S/T-NT Line (A-Law)
TN556C
Upper Left