Install and Cable the Cabinets
Page 1-86
Install Off-Premises Station Wiring
1
Figure 1-40
shows the connections for up to 24 off-premises analog telephones.
Concentrations of analog line pairs are used at both buildings to minimize the
off-premises wiring required. At the MDF, jumpers must be connected between 1
row/connecting block in the white field and up to 3 rows/connecting blocks in the
purple field. At the station location, a WP-90929, List 1 Concentrator Cable is
used. There are 8 station appearances on each of the 3 fingers of the
concentrator cable.
off-premises wiring required. At the MDF, jumpers must be connected between 1
row/connecting block in the white field and up to 3 rows/connecting blocks in the
purple field. At the station location, a WP-90929, List 1 Concentrator Cable is
used. There are 8 station appearances on each of the 3 fingers of the
concentrator cable.
Figure 1-40.
Connections to 24 Out-of-Building Telephones
Figure Notes
1. Locally engineered cables
2. Multi-pair protector units (primary
protectors with heat coils or equivalent with
sneak current protection)
sneak current protection)
3. B25A cable
4. Concentrator cable (WP90929 List 1)
5. 356A adapter
6. Out-of-building wiring
7. Out-of-building analog telephones
8. Part of MDF
9. Station side (white field)
10. System side (purple field)
11. Cross-connect jumpers
12. To TN2183, TN769, TN742, or
TN746B analog line circuit pack
crdf24o RPY 012398