Lucent Technologies 555-230-220 Manuale Utente

Pagina di 522
Installation and Test for CallVisor ASAI
14-8
Issue  7 May 1998 
In the CDR System Parameters form, the CDR Call Splitting field must be 
enabled if charging number is desired in the Charging Event Report 
change to reflect transfers and conferences. Lastly, the CDR adjuncts must 
be administered, or CDR Call Splitting will not take affect and will therefore 
not affect the ASAI charging events.
Answering Machine Detection — System-Parameters Customer-Options 
Features Form 
Reason Codes — System-Parameters Customer-Options and System 
Parameters Features Forms
Option for Switch-Classified Calls — System-Parameters 
Customer-Options Form 
Flexible Billing — System-Parameters Customer-Options Form. In 
addition, the following optional system features must be activated to 
support the MultiQuest Flexible Billing feature:
— ASAI for
 
Release 5: ASAI not needed when have tandeming. 
— ISDN   Primary Rate Interface (ISDN-PRI) 
— MultiQuest Flexible Billing: For a tandem ECS, the Flexible Billing 
option need not be active to tandem the NSF IEs to the next ECS. 
For a ECS providing VRU access without an AP, the Flexible Billing 
option need not be active to pass the NSF IEs to the VRU. The VRU 
must be equipped with a PRI interface and treated as if it were a 
trunk group to a tandem ECS.
Finally, the following optional system features will probably be used when 
Flexible Billing is active: 
— Automatic Call Distribution (ACD) — Required if call routing uses 
ACD I
— Call Vectoring — Required if inbound calls use Call Vectoring for 
routing 
Selective Listening — System Parameters Customer-Options Form
Call Classification After Answer Supervision — System Parameters 
Features Form
For detailed instructions regarding the administration of the above features, see 
the 
DEFINITY Enterprise Communications Server Implementation
 document, 
555-230-302.
CallVisor ASAI Link Testing
After the CallVisor ASAI link is administered and installed, perform the following 
tests as described in the 
DEFINITY Enterprise Communications Server 
Installation and Test for Single-Carrier Cabinets
, 555-230-894,
 or DEFINITY 
Enterprise Communications Server Installation and Test for Multi-Carrier 
Cabinets
, 555-230-112.