DELL 7.4 Manuale Utente

Pagina di 232
Severity
Error
Cause
An SD card device sensor in the specified system detected an error. The sensor 
location, chassis location, previous state, and SD card device type information is 
provided. The SD card state is provided if an SD card is present in the SD card 
device.
Event ID — 1755
Description
SD card device sensor detected a non-recoverable value Sensor 
location: <Location in chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
SD card device type: <Type of SD card device>
SD card state: <State of SD card>
Severity
Error
Cause
An SD card device sensor in the specified system detected an error from which it 
cannot recover. The sensor location, chassis location, previous state, and SD card 
device type information is provided. The SD card state is provided if an SD card is 
present in the SD card device.
Chassis Management Controller Messages
The Alerts sent by M1000e Chassis Management Controller (CMC) are organized by severity. That is, the 
event ID of the CMC trap indicates the severity (informational, warning, critical, or non-recoverable) of 
the alert. Each CMC alert includes the originating system name, location, and event message text. The 
alert message text matches the corresponding Chassis Event Log message text that is logged by the 
sending CMC for that event.
Event ID — 2000
Description
CMC generated a test trap.
Severity
Informational
Cause
A user-initiated test trap was issued, through the CMC GUI or RACADM CLI.
Event ID — 2002
Description
CMC reported a return-to-normal or informational event.
Severity
Informational
Cause
CMC informational event, as described in the drsCAMessage variable binding 
supplied with the alert.
53