Chauvet C-640FC Manuale Utente

Pagina di 48
EN 
Ovation™ C-640FC QRG 
AC Power 
This product has an auto-ranging power supply that can work with an input 
voltage range of 100-240 VAC, 50/60 Hz. 
 
 
Power Linking 
You can link up to 9  Ovation™ C-640FC  products at 120 VAC or 
 
18  at 230 VAC. Never exceed this number. Power linking cords can be 
purchased separately. 
 
 
AC Plug 
Connection 
Wire (U.S.) 
Wire (Europe) 
Screw Color 
AC Live 
Black 
Brown 
Yellow/Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
 
 
 
Replacing the 
Fuse  
1. 
Disconnect this product from power. 
2. 
Using a Phillips #2 head screwdriver, unscrew the fuse holder cap 
from the housing. 
3. 
Remove blown fuse and replace with a good fuse of the same type and 
rating. 
4. 
Screw the fuse holder cap back in place and reconnect power. 
 
 
DMX Linking 
The  Ovation™ C-640FC  will work with a DMX controller using a regular 
DMX serial connection. A DMX Primer is available from 
 
 
DMX Connection 
The  Ovation™ C-640FC  uses a regular DMX data connection for its DMX 
personalities: TOURTR16ARC.1AR1.DARC.2ARC.3AR3.DAR3.S, 
PIX1
,  PIX3PX16,and HSV. See the User Manual to connect and configure 
for DMX operation. 
 
 
 
Note: For optimum control of the 16-bit dimming channels in the TR16 
personality, be sure that the dimming curve in SET > DIMX is set to OFF. 
 
 
Master/Slave 
Connection  
The Ovation™ C-640FC uses the DMX data connection for its Master/Slave 
mode. See the User Manual to connect and configure for Master/Slave 
operation.