5.2.3
Finding Unused DMX Addresses
Figure 5.3. The View by DP view of the Fixture window
You can see an overview of all patched fixtures in the
Fixture
window by using View by DP;
see Figure 5.3, “The View by DP view of the Fixture window”. This shows a spreadsheet with
start address, fixture type and user number for each DMX universe. Additional rows show where
there is an available space in the allocated DMX addresses. This is useful when you are patching
additional fixtures and you need to know what ranges of DMX addresses are free. To show this
view:
Setup
 
 
Patch
 
 
View by DP
: the View by DP button is on the toolbar at
the top of the Fixture window.
You can use the buttons in the toolbar at the top of the window to view each group of four uni-
verses of a DMX Processor.
Deselect the View by DP button to return the Fixture window to its normal view.
5.2.4
Adding and Removing DMX Processors
All fixtures in the Hog 4OS are patched to DP8000s. The Hog 4OS automatically detects and
makes available any connected DP800s for patching but if you want to patch fixtures to DP8000s
that are not currently connected to the console, you must first add the DP8000s to the show:
1.
Setup
 
 
Patch
 
 
Patch @
: open the
Fixture Patch
window. The
Patch
@
button is on the toolbar at the top of the
Fixture
window.
2.
Press the
Add
button below the list of DP800s. The
Add DP
window will
open:
High End Systems
108
Section 5: Adding, Patching, and Managing Fixtures