4.
Hog 4OS cannot change a fixture's type while it is patched. You will be asked
if you want to unpatch any patched fixtures; don't forget to repatch them after-
wards.
Figure 5.9, “Changed Fixture Type” shows the contents of the Fixture window before and after
changing the fixture type.
»
Important
Changing a fixture's type may cause ambiguities in any programming
that has already taken place. Whilst Hog 4OS translates all real world
figure data, including colour and beam, between fixture functions, it
cannot match the performance of a higher specification unit with a
greater number of functions to that of a lower specification unit.
Figure 5.9. Changed Fixture Type
5.5
Removing a Fixture from the Show
To remove a fixture:
1.
Setup
 
 
Patch
: open the
Fixture
window.
2.
Fixture
1
Remove
: Select the fixture(s) you want to remove, and press
Remove
.
3.
You will be asked to confirm. Select
OK
.
»
Important
If you remove a fixture, all of its associated programming in groups,
palettes, cues and so on will be removed from the show. To disable a
fixture while retaining its programming, unpatch it; see Unpatching Fix-
tures (p.113)
.
5.6
Creating Palettes and Groups Automatically
Hog 4OS can create groups and palettes automatically, based on the fixtures in your show. This
rapidly gives you a set of ‘building blocks’ to start programming with. To use the
Auto Palettes
function:
High End Systems
116
Section 5: Adding, Patching, and Managing Fixtures