High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
You can add parameter, location and destination masks to any copy command:
1
Thru
4
Intensity Copy List
3
Cue
1
Fixture
8
Thru
11
,
Enter
: copies
the intensities of fixtures 1 to 4 in the current selection to fixtures 8 to 11 in
cue 1 of cuelist 3.
You can use Copy to reverse the order of values. For example, if fixture 1 is at 10%, fixture 2
at 20%, and fixture 3 is at 30%:
1
Thru
3
Copy
3
Thru
1
Enter
: the fixtures will now be at 30%, 20%
and 10% respectively.
Tip
When you press the Copy key, the words ‘Copy to’ appear on the com-
mand line. This is a useful reminder of the syntax of the copy command.
In the Programmer or Editor Window
You can copy fixture data by using the Copy and Paste commands: click the right-hand mouse
or Trackball button on the desired cell(s) in the editor window and select
Copy
or
Paste
from
the menu.
You can also use the
Pig
key to copy and paste selected cells:
Pig
+
Copy
: copy
Pig
+
Record
: paste
Copy Options
By default, when you copy parameter values from one fixture to another, the console will copy
exactly the data from one fixture to another, including any palette references. You can optionally
have the hard values from within the referenced palette copied to the destination instead of the
palette references:
1.
Fixture
1
: select the fixture you want to copy.
2.
Copy
3.
Deselect the
Allow Refs
button on the copy toolbar.
4.
8
: select the fixture to copy to.
5.
Enter
: copies the parameters of Fixture 1 to Fixture 8, converting any palette
references to hard values.
Tip
You can copy a fixture to itself with Allow Refs deselected to convert
palette references to hard values.
141
High End Systems
Section 6: Selecting Fixtures and Modifying Paramet-
ers