High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
8.6
Record Options
8.6.1
Global, Per Fixture Type, and Per Fixture
When you record a palette, parameter values can be recorded as global, per fixture type, or per
fixture. The three kinds work in different ways when you apply the palette to fixtures during
programming:
Global: the palette's parameter values are applied to all selected fixtures that
have that parameter. For example, a colour palette containing hue and saturation
parameters is applied to all selected fixtures that have hue and saturation.
Per Fixture Type: the palette's parameter values are applied to all fixtures of
that type. For example, a palette containing parameter values for Studio Color
575s will only be applied to selected Studio Color 575s.
Per Fixture: the palette's parameter values are applied only to those specific
fixtures that are both in the palette and selected in the editor. For example, a
palette containing parameter values for Studio Color 575 1 will only be applied
to that fixture (and only then if it is selected).
By default, the following rules determine how the palette is recorded:
1.
Position palettes are always recorded Per Fixture.
2.
If all the fixtures to be recorded have exactly the same parameter values, then
the palette is recorded as Global.
3.
Otherwise the palette is recorded Per Fixture.
In the palette's editor, the parameter values in a Global palette will appear as
All Types
. Similarly,
a palette with Per Fixture Type values will show them grouped by fixture type; see Figure 8.3,
“A Palette with Global Parameter Values”
Figure 8.4, “A Palette with Per Fixture Type Values”
and Figure 8.5, “A Palette with Per Fixture Values”. Make sure that you have aggregation turned
on; see Aggregation (p.41).
Figure 8.3. A Palette with Global Parameter Values
High End Systems
158
Section 8: Palettes