High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
tensity values in the Programmer with a fade time of ten seconds, and you select all of the fixtures
and press
@
0
Enter
, all of the lights would fade to 0 over 10 seconds. This is useful for making
changes on the fly during a performance.
Parameters that don't have timing values in the Programmer will fade in the default time, which
you can assign in the
Default Timing
pane of the
User Preferences
window:
Setup
 
 
Preferences
 
 
Default Timing
Press the
Fade Changes
button again to revert to having parameter values appear in the output
instantly.
To view and assign time values for parameters, see Individual Parameter Timings (p.206).
Tip
You can set a trackball key turn Fade Changes on and off; see Trackball
Keys (p.92)
.
16.5.2
Blind
Blind mode allows you to continue programming and editing cues, groups, palettes and scenes
without changing the onstage parameter values of fixtures. The
Blind
key is located above the
Trackball; when in blind mode, the
Blind
key will illuminate.
Note that when you turn off blind mode all parameter values that you have changed in the Pro-
grammer or editor will instantly appear on stage.
To exit blind mode gracefully, hold down the
Pig
key while pressing
Blind
; parameters will fade
to their new values in the assigned or default fade time. Alternatively, select
Fade Changes
in
the editor you are using prior to turning blind on or off.
Tip
Using Pig + Blind on Hog 4OS is equivalent to using the Try Cue key on
the Wholehog II.
16.6
Parking
Sometimes it is useful to lock certain parameter values of fixtures independently from program-
ming, playback and the Grand Master. For example, you might want to lock a particular dimmer
at a certain level as a working light, or point a fixture to provide light for maintenance whilst a
rehearsal or programming is in progress. Park is also helpful for dealing with a fixture malfunction,
locking its pan and tilt so that it doesn't make a noise as it tries to move during the show.
Parking holds a fixture's parameters on stage, but still allows you to edit the data in the Program-
mer or other editors.
247
High End Systems
Section 16: Advanced Programming