High End Systems 2.0.0-EN Manuale Utente
Notes
De-
fault
fault
Timing Function
The time over which parameter values go to their
default values when the cuelist is released; see
Releasing Masters (p.255).
default values when the cuelist is released; see
Releasing Masters (p.255).
2s
Release Time
The time in which parameters go to their values de-
termined by the cuelist when the cuelist is asserted;
see Asserting One Cuelist Over the Others (p.266).
termined by the cuelist when the cuelist is asserted;
see Asserting One Cuelist Over the Others (p.266).
2s
Assert Time
The time in which the cuelist steps back to the previ-
ous cue when the Halt key is pressed twice (to first
halt the cuelist and then send it back).
ous cue when the Halt key is pressed twice (to first
halt the cuelist and then send it back).
2s
Back Time
Default proportion rate of the cuelist. A rate of 50%
will double all cue timings, a rate of 200% will halve
all cue timings.
will double all cue timings, a rate of 200% will halve
all cue timings.
100%
Cuelist Rate
Releases previous cue's tracking values as you ad-
vance the list to the next cue. Tracking values are
released using the total fade time of the cue being
played.
vance the list to the next cue. Tracking values are
released using the total fade time of the cue being
played.
Off
Cue Only
Tip
If you have assigned a release, assert or back time to a cuelist, and you
want to revert to the default time, press the Default button adjacent to
the appropriate cell.
want to revert to the default time, press the Default button adjacent to
the appropriate cell.
Cuelist Wrapping
Wrapping decides what happens to a cuelist when it reaches the final cue. Configure the wrapping
in the
in the
Action at End of List
menu:
•
Wrap to beginning of list: Pressing Go after the final cue is reached sends the
cuelist to its first cue.
cuelist to its first cue.
•
Add release end cue: Pressing Go after the final cue is reached releases the
list and sends it to its first cue.
list and sends it to its first cue.
•
Auto-release at end: The cuelist is released as soon as the last cue in the
cuelist has completed all its fade and delay times.
cuelist has completed all its fade and delay times.
•
Don't allow wrapping: The cuelist stays on the final cue until released or sent
backwards.
backwards.
Cue Only
Cue Only enables a cuelist to playback cue data one cue at a time (otherwise known as a non-
tracking cuelist). For example: any cue data in cue 1 is released as you play cue 2 so that only
data from cue 2 is onstage. The release time of the previous cue is determined by the longest
fade time in the cue being played.
tracking cuelist). For example: any cue data in cue 1 is released as you play cue 2 so that only
data from cue 2 is onstage. The release time of the previous cue is determined by the longest
fade time in the cue being played.
High End Systems
260
Section 17: Playback