High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
Notes
De-
fault
Timing Function
The time over which parameter values go to their
default values when the cuelist is released; see
Releasing Masters (p.255).
2s
Release Time
The time in which parameters go to their values de-
termined by the cuelist when the cuelist is asserted;
see Asserting One Cuelist Over the Others (p.266).
2s
Assert Time
The time in which the cuelist steps back to the previ-
ous cue when the Halt key is pressed twice (to first
halt the cuelist and then send it back).
2s
Back Time
Default proportion rate of the cuelist. A rate of 50%
will double all cue timings, a rate of 200% will halve
all cue timings.
100%
Cuelist Rate
Releases previous cue's tracking values as you ad-
vance the list to the next cue. Tracking values are
released using the total fade time of the cue being
played.
Off
Cue Only
Tip
If you have assigned a release, assert or back time to a cuelist, and you
want to revert to the default time, press the Default button adjacent to
the appropriate cell.
Cuelist Wrapping
Wrapping decides what happens to a cuelist when it reaches the final cue. Configure the wrapping
in the
Action at End of List
menu:
Wrap to beginning of list: Pressing Go after the final cue is reached sends the
cuelist to its first cue.
Add release end cue: Pressing Go after the final cue is reached releases the
list and sends it to its first cue.
Auto-release at end: The cuelist is released as soon as the last cue in the
cuelist has completed all its fade and delay times.
Don't allow wrapping: The cuelist stays on the final cue until released or sent
backwards.
Cue Only
Cue Only enables a cuelist to playback cue data one cue at a time (otherwise known as a non-
tracking cuelist). For example: any cue data in cue 1 is released as you play cue 2 so that only
data from cue 2 is onstage. The release time of the previous cue is determined by the longest
fade time in the cue being played.
High End Systems
260
Section 17: Playback