17.7
Inhibitive Masters
Inhibitive masters allow you to limit the intensity of a group of fixtures. If the inhibitive master
is at full, then the fixtures that it controls will be at the level determined by the playbacks, Pro-
grammer, and so on. As the inhibitive master level is reduced, the fixture intensities will be re-
duced in proportion. For example, if you have four fixtures at 0%, 50%, 80% and 100% in a cue
that is being output, and these fixtures are also in an inhibitive master, then the levels will change
as follows:
is at full, then the fixtures that it controls will be at the level determined by the playbacks, Pro-
grammer, and so on. As the inhibitive master level is reduced, the fixture intensities will be re-
duced in proportion. For example, if you have four fixtures at 0%, 50%, 80% and 100% in a cue
that is being output, and these fixtures are also in an inhibitive master, then the levels will change
as follows:
4
3
2
1
Fixture:
100
80
50
0
Master at 100%
50
40
25
0
Master at 50%
0
0
0
0
Master at 0%
Pressing the Flash key of an inhibitive master is the same as momentarily changing its fader
level to 0%, taking all fixture intensities controlled by the inhibitive master to 0%. Intensity
values are restored when you release the key.
level to 0%, taking all fixture intensities controlled by the inhibitive master to 0%. Intensity
values are restored when you release the key.
To create an inhibitive master:
1.
Record a group containing the required fixtures. See Recording Groups (p.149).
2.
Group
,
Group
: open the Group Directory.
3.
Select the required group. To ensure you don't select the group in the Program-
mer or editor, enable the Guard button in the Group Directory, or press and
hold the Pig key while selecting the group.
mer or editor, enable the Guard button in the Group Directory, or press and
hold the Pig key while selecting the group.
4.
Move
,
Choose
: move the group to the required master.
Or, using the command line:
1.
Record a group containing the required fixtures.
2.
Group
[group number]
Move Choose
The Playback Bar will show the group name above the chosen master. When the master level is
less than 100%, the Playback Bar will also display a bar showing the level. When the Flash key
is pressed, the Playback Bar will display
less than 100%, the Playback Bar will also display a bar showing the level. When the Flash key
is pressed, the Playback Bar will display
BO
High End Systems
282
Section 17: Playback