High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
ideas of intensity, colour, and so on into the specific instructions that the fixtures need, defined
by their DMX protocol.
2.3.1
Referring to Fixtures
The Hog 4OS treats every fixture as a single entity. Every fixture is assigned a user number that
allows users to easily recall a fixture and manipulate it's feature set no matter how many parameters
it has. For more information on giving your fixtures custom user numbers , see Modifying the
User Number (p.119)
.
Hog 4OS treats conventional lights, consisting of a luminaire controlled by a dimmer, as a special
kind of fixture known as a ‘desk channel’. A desk channel has only one parameter: intensity.
2.3.2
Real World Units
Fixture parameters are described as far as possible in real world units. For example, rotation is
described in degrees while chases are described in beat per minute. This speeds up programming
and allows fixtures of different types to be selected and adjusted at the same time: for example,
you can assign several fixtures of different types to all strobe at 10 Hz without having to worry
about the different DMX values required by each fixture to achieve this. Hog 4OS will give you
the best possible match between fixtures; the only limitations are those of the fixtures themselves.
2.3.3
Complex Parameters
Some fixtures put more than one parameter onto a single DMX address. For example, a fixture
might use DMX values in the range 0-127 for intensity, 128-250 for strobe, and 251-255 for
fixture reset. The Hog 4OS separates such functions into independent parameters, so that you
do not need to remember the detailed workings of a particular fixture; in the example given
above, the intensity, strobe and reset functions all appear as separate parameters, so there is no
possibility of going from strobe into reset. With parameters that share a DMX address, changing
the value of one will override the value of all the others, since there can only be one DMX value.
In the case of our example, assigning a strobe speed will override any intensity value; the console
will show a ~ in place of the intensity value to indicate that this has happened.
2.3.4
Interchangeable Fixtures
Any fixture already programmed into a show can be replaced by a fixture of a different type at
any time and Hog 4OS will as far as possible convert the programmed data to apply to the new
fixture type. If the new fixture has more limited capabilities than the old one, this is handled as
gracefully as possible. For more on replacing fixtures, see Changing the Fixture Type (p.115).
High End Systems
30
Section 2: Hog 4OS Fundamentals