High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
Lamp Control commands from Strobe channel:
1.
Select the function cell for a blank DMX Entry of channel 10 and press
Set
.
A dialog will appear with a list of function categories.
2.
Select Control on the left column to display a list of Control function sub-
categories.
3.
Select Lamp Control as the desired function. The window will close and you
will see Lamp Control assigned as the function for channel 10. Note the feature
column will auto-fill with ‘Strike’. Select this cell and press
Set
. Choose
Douse from the dialog box.
4.
Select the DMX value cell for this DMX Entry and press
Set
. Enter the DMX
for the lamp douse according to the DMX protocol (245) and press
Enter
.
5.
Repeat the above steps for the lamp strike ability of the fixture.
Note that Real World values are not allowed for Lamp Control functions.
25.2.4
Step 4: Build the Fixture
Your fixture should be similar to the example below:
High End Systems
364
Section 25: The Fixture Builder