High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
To enable console failover:
1.
Connect two consoles via an Ethernet switch.
2.
Enable the
Run Server
option in the
Settings
window on each console.
3.
Configure the primary console as Net number 1 and the secondary console as
Net number 2.
4.
Log on primary console and then connect secondary console.
After configuring the network for failover, each console connected to the show will monitor the
status of the primary console (the console that first loaded the show on the network) for any
failures or forced log offs.
In the event that the primary console suffers a critical error or is disconnected from the network,
all other consoles connected to the show will post the message shown below, notifying the user
that a failover has occurred and indicated which of the other server consoles has taken over as
the active show server (primary console).
73
High End Systems
Section 3: Setting Up the System