Although the manufacturer has attempted to ensure that your grill will operate properly and satisfactorily, 
sometimes problems do arise.  The following troubleshooting guide lists several possible problems and 
their probable cause and solution.
Problem
Cause
Solution
Burner will not light.
Gas injector not inserted in venturi 
tube.
Realign/engage gas injector with 
the venturi tube.
Clogged gas injector.
Remove gas injector from gas con-
trol assembly and clean.
Obstruction in gas line.
For propane models, ensure gas 
valve on cylinder is OFF. Remove 
flexible hose and blow out any 
debris.
Spider webs in venturi tubes.
Clean venturi tubes. See Mainte-
nance Section.
Misalignment of collector box and 
burner.
Position electrode properly. Clean 
collector box.
Out of gas
Refill LP gas cylinder. If natural 
model, turn on gas at source.
Dead battery.
Replace with AA Alkaline battery.
Inadequate grill tem-
perature.
Poor combustion.
Adjust air shutter.
Misalignment of venturi tube and 
gas injector.
Realign/engage gas injector with 
the venturi tube.
Inadequate gas pressure.
Contact gas supplier for assistance.
Incorrect orifice/valve setting.
Refer to gas conversion instructions 
in this manual.
Flames blow out.
Cold grill.
Preheat grill at least 5 minutes on 
HI with the grill lid closed.
Misalignment of burner tube and 
gas injector.
Realign/engage gas injector with 
the burner tube.
Poor combustion.
Adjust air shutter.
Extreme wind.
Turn or shield grill.
Yellow flames.
Air shutter improperly set.
Open air shutter
Spider webs in venturi tubes.
Clean venturi tubes. See Mainte-
nance Section.
Seasoning salts on burner.
Clean by washing burner with mild 
detergent.
Oil film on burner.
Allow burner to operate on HI for 
10-15 minutes.
TROUBLESHOOTING