Broilmaster R3-1 Manuale Utente

Pagina di 56
B101623-5-1012
Page 42
1.  R3B Grills: Remove cooking grids, briquets and briquet rack 
from grill.
2.  Blue  Flame  Burner:  Remove  blue  flame  burner  shield  and 
blue flame burner from grill (one (1) 1/4-20 x 3/4 phillips screw 
for burner). 
See Figure 36. Infrared Burner: Remove ignitor 
wire, lugs and infrared burner from grill (one (1) 1/4-20 x 3/4 
phillips screw for each burner). 
See Figure 36.
3.  Remove  LP  burner  orifices  marked  1.25 mm  for  R3B.  Re-
move LP burner orifice marked 1.3 mm for R3. 
See Figure 
37.
4.  Install natural gas burner orifice marked 49 into each orifice 
fitting. Apply pipe compound to threads on orifices prior to in-
stallation.
5.  Blue Flame Burner: Place burner shield and burners into 
grill  and  insert  burner  tubes  over  orifice  fittings.  Secure 
each burner with one (1) 1/4-20 x 3/4 phillips screw from 
Step 
2. 
      
Infrared Burner: Place infrared burners, ignitor, and lugs into 
grill and insert burner tubes over orifice fittings. Secure each 
burner with one (1) 1/4-20 x 3/4 phillips screw from step 2.
6.  Grasp valve knobs and remove from valves.
7.  The low input adjustment screws are located inside the two 
valve stems. Use a small screwdriver to turn each adjustment 
screw clockwise 1/4 turn (90 degrees). When valves are in 
the "OFF" position, the slot in the adjustment screw should be 
vertical. 
See Figure 38.
8.  Remove the hose and regulator from the gas connection on 
grill with adjustable wrench.
9.  Connect the grill to the natural gas supply. 
 
Attention:   Before lighting your grill check all gas con-
nections including the adjustment screws in valve stems 
for gas leaks with a soapy water mixture. 
 
Caution: Do not use the grill if a gas leak is detected until gas 
leak is corrected. If a gas leak can not be stopped, do not use 
grill. You must contact a qualified repair person.
10.  Push valve knobs onto valves.
11.  Apply the completed conversion label adjacent to the rating 
plate label on the grill.
Figure 37
LPG
NAT
ADJUSTMENT SCREW
ADJUSTMENT SCREW
Figure 38
R3B
R3
Figure 36
GAS CONVERSION TO NATURAL GAS