Gas Connection
www.calflamebbq.com
10
Gas Requirements and Connection
IMPORTANT:  The Cal Flame grill is manufactured to operate on liquid propane (LP). However, it can be 
converted to operate on natural gas (NG) by an authorized service technician. Consult your Cal Flame dealer 
for information on converting your gas grill.
Owners must not convert their grills themselves . Attempting to convert the grill from LP to NG 
may result in serious injury and will void the warranty coverage . 
If you do not have an updated filler valve on your existing propane tank, you will need to purchase one at 
your local hardware store.  Without it you will not be able to attach your tank to your Cal Flame™ grill or 
refill the tank at your local propane refill station.
Leak Testing Procedure
Perform a leak test at least once a year whether the 
gas  supply  cylinder  has  been  disconnected  or  not. 
In addition, whenever the gas cylinder is connected 
to  the  regulator  or  whenever  any  part  of  the  gas 
system is disconnected or replaced, perform a leak 
test.  
As a safety precaution, remember to always leak test 
your grill outdoors in a well-ventilated area.  Never 
smoke or permit sources of ignition in the area while 
doing  a  leak  test.    Do  not  use  a  flame,  such  as  a 
lighted  match  to  test  for  leaks.  Use  a  solution  of 
soapy water.
Prepare a leak testing solution of soapy water by 
1. 
mixing in a spray bottle one part liquid soap to 
one part water.
Make sure all the control knobs are in the OFF 
2. 
position.
Turn on the gas.
3. 
On 
a. 
natural gas systems, turn the main feed 
valve to the grill.
On 
b. 
LP systems, turn the cylinder valve knob 
counter clockwise one turn to open.
Apply  the  leak-testing  solution  by  spraying  it 
4. 
on  joints  of  the  gas  delivery  system.  Blowing 
bubbles in the soap solution indicates that a leak 
is present.
Stop a leak by tightening the loose joint or by 
5. 
replacing  the  faulty  part  with  a  replacement 
part  recommended  by  the  manufacturer.  Do 
not attempt to repair the cylinder valve if it is 
damaged. The cylinder must be replaced.
Turn  all  control  knobs  back  to  the  full  OFF 
6. 
position.
If you are unable to stop a leak:
Turn  all  control  knobs  back  to  the  full  OFF 
1. 
position.
 Shut off the gas supply to the grill and release 
2. 
pressure  in  the  hose  and  manifold  by  pushing 
in  and  turning  any  of  the  control  valves  one 
quarter turn counter-clockwise.
 On LP systems, remove the cylinder from the 
3. 
grill.
Call  an  authorized  gas  appliance  service 
4. 
technician or an LP gas dealer.
Do not use the appliance until the leak is corrected.
Gas Connection