Regency U41-3 ULTIMATE Gas Fireplace Insert
HIGH ELEVATION
This unit is approved in Canada for altitude 2000 ft. to 4500 ft. (CAN/CGA-
2.17-M91) with the orifi ce kit Part # 611-975. For Natural Gas installations 
above 4500 ft. follow current CAN/CGA-B149.1.
In U.S.A., for installations above 2000 ft. refer to current ANSI Z223.1 
Sc8-8.1.2a appendix F, for resizing orifi ce.
INSTALLATION
Note:  A non-combustible mantel may be installed at a lower height if the framing is made 
of metal studs covered with a non-combustible board.
System Data
For 0 to 2000 feet altitude
Burner Inlet Orifi ce Sizes:
 
                Natural Gas     Propane
Burner #32 
#50
 
 
 
*Above 2000 ft. see National Code Orifi ce Chart.
Max. Input - Natural Gas/Propane   38,000 btu/h
Min. Input - Natural Gas/Propane   
20,000 
btu/h
Min. Output Capacity with blower Off 
 
Natural Gas 
27,550 btu/h
 Propane 
27,778 
btu/h
Max. Output Capacity with blower On 
 
Natural Gas 
29,184 btu/h
 Propane 
29,260 
btu/h
Supply Pressure:   Natural Gas  min.  5" w.c.
 
 
 Propane 
min. 
12" 
w.c.
 
 
Manifold Pressure
Natural Gas 
3.8"   +/- 0.2" w.c.
Propane 
11"   +/- 0.2" w.c.
  
  Burner Inlet Orifi ce Sizes:
 
            Natural Gas 
   
 Burner 
#33 
  
 
  Max. Input Rating - Natural Gas 34,000 btu/h
  Min. Input Rating - Natural Gas 18,000 btu/h
   
        
     Output Capacity with blower Off 
 Natural 
Gas 
24,786
 
  Max. Output Capacity with blower On 
 Natural 
Gas 
26,146
System Data - HIGH ELEVATION
For 2,000 - 4,500 feet altitude
Combustible Mantel Clearances
Depth (Mx)  5-1/2" 
6" 6-1/2" 
7" 7-1/2" 
8" 8-1/2" 
9" 9-1/2" 
 
Clearance (My)  11" 
11-3/8" 11-3/4" 12-1/4" 12-1/2" 12-5/8" 12-3/4" 12-7/8" 13"
Non-combustible Hearth Extension
Height (Hy
0"  5/8"  1-1/4" 1-7/8" 2-3/8" 2-3/4" 3-1/8" 3-1/2" 3-3/4" 4" 
 
 
 
 
 
Depth (Hx)  25" 
24" 23" 22" 21" 20" 19" 18" 17" 16"