Desa VM42P Manuale Utente

Pagina di 32
www.desatech.com
108795-01N
21
INSPECTING BURNERS
Continued
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. 
Flames should go up through the middle of logset. 
Flames should not "spill" to the edges of the pan 
or sides of the logset.
Figure 43 shows a typical flame pattern. If burner 
flame pattern differs from that described:
•  turn appliance off (see To Turn Off Gas to Ap-
pliance, page 20) 
•  see Troubleshooting, page 23
Thermopile
Pilot 
Burner
Ignitor
Figure 42 - Correct Pilot Flame Pattern
Figure 43 - Typical Flame Pattern
CLEANING AND 
MAINTENANCE
 WARNING: Installation and 
repair should be done by a quali-
fied service person. The appli-
ance should be inspected before 
each use and at least annually 
by  a  qualified  service  person. 
More frequent cleaning may be 
required  due  to  excessive  lint 
from  carpeting,  bedding  mate-
rial, pet hair, etc. It is imperative 
that the control compartments, 
burners and circulating air sys-
tem be kept clean.
 WARNING: The logs can be 
hot. Handle only when cool.
 WARNING: Turn off gas and 
electrical power before servicing 
appliance.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
PILOT AND BURNER
•  Remove  logs  and  ember  material  before 
cleaning burner and replace when cleaning is 
complete.
•  Burner and controls should be cleaned with 
compressed air to remove dust, dirt or lint.
•  Use a vacuum cleaner or small, soft bristled 
brush to remove excess dust, dirt or lint.
LOGS
•  If you remove logs for cleaning, refer to log 
placement information on page 12  to properly 
replace logs.
•  Use a vacuum cleaner to remove any carbon 
buildup on logs.
•  Replace  log(s)  if  broken.  See  Replacement 
Parts, page 22.
•  Replace ember material periodically as needed. 
See Replacement Parts, page 22.