Desa VM42P Manuale Utente

Pagina di 32
www.desatech.com
108795-01N
5
  WARNING:  Installation  of 
this appliance should be done 
by  a  qualified  service  person 
well  trained  in  the  installation 
of  such  appliances.  You  will 
also need a building permit from 
your local Building and Safety 
Commissioner before installing 
this  appliance;  otherwise  your 
insurance co. may not cover this 
appliance.
NOTICE:  This  appliance  is  not 
intended to be used as a primary 
source of heat.
  CAUTION:  Do  not  connect 
appliance before pressure test-
ing gas piping. Damage to gas 
valve may result and an unsafe 
condition may be caused.
The appliance and itʼs individual shutoff valve 
must be disconnected from the gas supply piping 
system during any pressure testing of that system at 
test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual 
shutoff valve during any pressure testing of the gas 
supply piping system at test pressures equal to or 
less than 1/2 psig (3.5 kPa).
For the purpose of input adjustment two pressure 
taps (for IN and OUT pressures) are provided on 
the gas control valve for test gauge connections 
to the appliance.
INTRODUCTION
Continued
Figure 1 - Possible Locations for 
Installing Appliance 
INTERNAL WALL
INSTALLATION
CORNER
INSTALLATION
FULL
PROJECTION
INSTALLATION
FLUSH
INSTALLATION
SELECTING LOCATION
To determine the safest and most efficient location 
for your appliance, you must take into consider-
ation the following guidelines:
1.  The location must allow for proper clearances 
(see Clearances, page 7).
2.  Consider a location where heat output would 
not  be  affected  by  drafts,  air  conditioning 
ducts, windows or doors.
3.  A location that avoids the cutting of joists 
or roof rafters will make installation easier. 
Figure 1 shows a plan view of a few common 
locations.
Flush  installations
 are recommended where 
living space is limited or at a premium and since 
the space required to enclose the appliance would 
be located beyond an outside wall, this would also 
reduce the cutting of joists, roof rafters and such. 
Check local codes for any restrictions.
Projected installations
 can extend any distance 
into the room. A projection may be ideal for a new 
addition on an existing, finished wall.
Corner installations
 make use of space that may 
not normally be used and provides a wider and 
more efficient range for radiant heat transference.
Internal wall installations
 provide a discreet 
option for room separation and can also be ideal 
as an addition to an existing wall.