TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Spark ignitor will not light pilot after re-
peated triggering of red button
Fireplace produces a clicking/ticking noise 
just after burner is lit or shut off
POSSIBLE CAUSE
1.  Defective  ignitor  (no  spark  at  elec-
trode)
2.  Defective pilot or misaligned electrode 
at pilot (spark at electrode)
3.  No gas or low gas pressure
4.  If using propane/LP gas, no propane/LP 
gas in tank
1.  Metal expanding while heating or con-
tracting while cooling
REMEDY
1.  Check  for  spark  at  the  electrode  and 
pilot; if no spark and electrode wire is 
properly connected, replace ignitor
2.  Using a match, light pilot. If pilot lights, 
turn off pilot and trigger the red button 
again. If pilot lights, an improper gas/air 
mixture caused the improper lighting 
and  a  longer  purge  period  is  recom-
mended. If pilot will not light, check 
gap at electrode and pilot. Gap should 
be 1/8" to have a strong spark. If okay, 
replace pilot
3.  A) Check remote shut off valves from 
fireplace. Usually there is a valve near 
the fireplace and sometimes there is a 
valve near the main. There can be more 
than one (1) valve between the fireplace 
and main
  B) Low pressure can be caused by a va-
riety of situations such as bent line, too 
narrow diameter of pipe or even low line 
pressure. Check for kinked lines. If none, 
consult with plumber or gas supplier
4.  Check propane/LP supply and contact 
local propane/LP supplier
1.  This is common with most fireplaces. 
If noise is excessive, contact qualified 
service person