Turbosound TA-500H Manuale Utente

Pagina di 73
user manual 
TA-500 
TA-500 user manual 
Page 44 
Front Panel Functions 
 
2x 24 character
LCD
Input Signal
Indicators
Store and
Recall buttons
Channel Select
buttons
Parameter Edit
Encoders
Output Mute
buttons
Limiter
Indicators
Edit Parameter
Select buttons
 
 
Input Signal Indicators
 – A set of three pairs of LED’s indicate signal present, +4dBu and input 
clip for both channels. The signal present LED’s operate at approximately –40 dBu, giving a 
useful indication of even relatively low input signal levels. The +4 dBu LED’s are intended to 
show nominal operating level and can also be useful for setting system gain structure. Clip 
LED’s warn the user of input overload and operate at +19 dBu. 
Program Store and Recall – these controls provide access to 45 presets. Pressing the store 
button allows the user to name a preset and choose which memory location it will be held in. 
Pressing store button again completes the process. The Recall function operates in a similar 
way, pressing the recall button allows the user to select which preset they require, pressing 
the button for a second time, then confirming, recalls the new DSP settings. The unit allows 
the user to set up user programs with full access to all parameters. 
 
Note that presets cannot be stored or recalled when secure mode is activated. 
Channel Selection Buttons – the currently selected channel is displayed on the top left hand 
corner of the LCD. Pressing the channel buttons scrolls through the available input and 
output channels and finally through the utility functions and back to the default screen. If 
operating a stereo-linked preset the channel name will indicate the channel pairing. For 
example ‘A+B’ means both input A and B parameters. The name of the output will be shown 
briefly at the top of the display when stepping onto an output. 
Edit Select Buttons – the currently selected edit parameter is displayed on the bottom left 
corner of the LCD. Pressing the edit select buttons moves through the available parameters 
for the current input or output.