PRODUCT FEATURES
These are a few facts that can help you understand and enjoy your 
direct-vent fireplace:
•  The venting system may be routed to the outside of your home 
in several ways. It may vent through the roof (vertical) or it may 
vent to an outside/exterior wall (horizontal). The vent pipe instal-
lation is very important to allow for proper operation. You must 
follow the venting instructions very carefully for either vertical 
or horizontal applications.
•  This fireplace may be installed in any room of your house provided 
all local codes and these installation instructions are followed.
•  The blower requires electricity if installed. If you plan to install 
the blower at a later date, do not forget to wire the outlet at the 
bottom of the fireplace when framing.
•  Each time you turn on your fireplace, you may notice some 
amount of condensation on the inside of the fireplace glass. This 
is normal and will disappear after 10-20 minutes of operation.
•  Your direct-vent gas fireplace system (fireplace and venting) is a 
balanced and sealed gas operating unit. It requires approximately 10-
20 minutes of operating time before the flame pattern stabilizes.
PRE-INSTALLATION 
PREPARATION
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient location for your DESA 
direct-vent fireplace. Make sure that rafters and wall studs are not 
in the way of the venting system. Choose a location where the heat 
output is not affected by drafts, air conditioning ducts, windows 
or doors. Figure 2 shows some common locations. Be aware of all 
restrictions and precautions before deciding the exact location for 
your fireplace and termination cap.
When deciding the location of your fireplace, follow these rules:
•  Do not connect this fireplace venting to a chimney flue serving 
a separate solid-fuel burning fireplace or appliance.
•  Due to high temperatures, do not locate this fireplace in high traf-
fic areas, windy or drafty areas or near furniture or draperies.
•  Proper clearances must be maintained.
•  If your fireplace is to be installed directly on carpeting, vinyl tile 
or any combustible material other than wood, it must be installed 
on a metal or wood panel extending the full width and depth of 
the fireplace. See Figure 3.
•  Your fireplace is designed to be used in zero clearance instal-
lations. Wall or framing material can be placed directly against 
any exterior surface on the back, sides or top of your fireplace, 
except where standoff spacers are integrally attached. If standoff 
spacers are attached to your fireplace, these spacers can be placed 
directly against wall or framing material. See framing details on 
page 5.
•  If you plan on installing a television or entertainment center re-
cessed above your fireplace, it is recommended that you maintain 
a minimum 18" above top of louver opening.
•  When locating termination cap, it is important to observe the 
minimum clearances shown in Figure 7, page 6.
•  If recessing into a wall, you can avoid extra framing by position-
ing your fireplace against an already existing framing member.
•  Do not recess termination cap into a wall or siding.
•  You may paint the termination cap with 450ºF (232ºC) heat-
resistant paint to coordinate with the exterior finish.  
•  There must not be any obstruction such as bushes, garden sheds, 
fences, decks or utility buildings within 24" from the front of the 
termination cap.
•  Do not locate termination cap where excessive snow or ice build up 
may occur. Be sure to clear vent termination area after snow falls to 
prevent accidental blockage of venting system. When using snow 
blowers, do not direct snow towards vent termination area.
PRODUCT FEATURES
PRE-INSTALLATION PREPARATION
Location and Space Requirements
Figure 2 - Common Fireplace Locations
Flush with a wall
Through exterior wall 
enclosed in a chase
Corner 
installation
Figure 3 - Fireplace Bottom Dimensions
D
RW
FW
29"
21 
1
/
8
"
41"