Figure 29 - Blower Wiring Diagram for Thermostat-Controlled 
Models 
Blower Wiring Diagram
 CAUTION: Label all wires prior to disconnection 
when  servicing  controls.  Wiring  errors  can  cause 
improper  and  dangerous  operation.  Verify  proper 
operation after servicing. 
Blue
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115 
V.A.C.
Blower
Motor
Black 
Off
1
2
Black
INSTALLING GAS PIPING TO FIREPLACE 
LOCATION
 WARNING: A qualified service person must con-
nect fireplace to gas supply. Follow all local codes.
 CAUTION: For propane/LP units, never connect 
fireplace  directly  to  the  propane/LP  supply.  This 
heater requires an external regulator (not supplied). 
Install the external regulator between the fireplace 
and propane/LP supply. 
Installation Items Needed
Before  installing  fireplace,  make  sure  you  have  the  items  listed 
below.
•  external regulator (supplied by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection *
•  sediment trap
•  tee joint
•  pipe wrench
•  approved flexible gas line with gas connector (if allowed by local 
codes)
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap 
is an acceptable alternative to test gauge connection. Purchase the 
CSA design-certified equipment shutoff valve from your retailer.
For propane/LP connection only, the installer must supply an ex-
ternal regulator. The external regulator will reduce incoming gas 
pressure. You must reduce incoming gas pressure to between 11 
and 14 inches of water. If you do not reduce incoming gas pressure, 
fireplace regulator damage could occur. Install external regulator 
with the vent pointing down as shown in Figure 30. Pointing the 
vent down protects it from freezing rain or sleet.
Figure 30 - External Regulator with Vent Pointing Down 
(Propane/LP Only)
Propane/LP 
Supply Tank 
External 
Regulator 
Vent 
Pointing 
Down 
FIREPLACE INSTALLATION
Installing Optional Blower Accessories (Cont.)
Installing Gas Piping to Fireplace Location
FIREPLACE INSTALLATION
Continued
5.   Mount the speed control box against the mounting plate provided 
in the lower fireplace cavity by placing the plastic control shaft 
forward through the round hole (see Figure 26, page 17).
6.  While supporting speed control, secure control shaft with lock 
nut by pushing and turning lock nut with pliers clockwise until 
it is tight against mounting plate. Place control knob provided 
on shaft (see Figure 26, page 17).
7.   Check to make sure that the power cord is completely clear of the 
blower wheel and that there are no other foreign objects in blower 
wheel. Also double check all wire leads and make sure wire routing 
is not pinched or in a precarious position. Correct accordingly. 
8.  Turn on power to duplex outlet if previously turned off per the 
warning in column 2, page 16.
9.   Plug in blower power cord to duplex outlet.
10.  The blower will only run when the speed control knob is in the 
ON position and the thermal switch senses temperature after the 
fireplace begins to heat up. The blower speed can be adjusted by 
rotating the control knob. To turn off, turn knob fully counterclock-
wise until it clicks off. If the blower is ON and has been running 
with the fireplace operating, the blower will continue to run for a 
short time after the fireplace has been turned off. As the thermal 
switch cools down, the blower shuts down automatically.
11.  Peel off the backing paper and stick the supplied wiring diagram 
decal on the firebox bottom approximately 12" in front of the 
blower (see Figure 27, page 17).