Thermal Specifications and Design Considerations
5.3.2.3
PECI Fault Handling Requirements
PECI is largely a fault tolerant interface, including noise immunity and error checking 
improvements over other comparable industry standard interfaces. The PECI client is 
as reliable as the device that it is embedded in, and thus given operating conditions 
that fall under the specification, the PECI will always respond to requests and the 
protocol itself can be relied upon to detect any transmission failures. There are, 
however, certain scenarios where the PECI is know to be unresponsive.
Prior to a power-on RESET# and during RESET# assertion, PECI is not assured to 
provide reliable thermal data. System designs should implement a default power-on 
condition that ensures proper processor operation during the time frame when reliable 
data is not available via PECI.
To protect platforms from potential operational or safety issues due to an abnormal 
condition on PECI, the Host controller should take action to protect the system from 
possible damage. It is recommended that the PECI host controller take appropriate 
action to protect the client processor device if valid temperature readings have not 
been obtained in response to three consecutive GetTemp()s or for a one second time 
interval. The host controller may also implement an alert to software in the event of a 
critical or continuous fault condition. 
5.3.2.4
PECI GetTemp0() Error Code Support
The error codes supported for the processor GetTemp() command are listed in 
:
§ §
Table 27.
GetTemp0() Error Codes
Error Code
Description
8000h
General sensor error
8002h
Sensor is operational, but has detected a temperature below its operational 
range (underflow)