DeVillbiss Air Power Company XC2600 Manuale Utente

Pagina di 60
18- ENG 
A20116
TROUBLE SHOOTING GUIDE
PROBLEM
Engine will 
not start (see 
Engine Manual 
for further 
engine 
troubleshooting)
CAUSE
CORRECTION
No fuel.
Add Fuel.
Pressure builds up after two pulls 
on the recoil starter or after initial 
use.
Squeeze gun trigger to relieve
pres sure.
Spark plug wire not attached.
Attach spark plug wire.
Choke lever in the "Choke" 
position on a "hot" engine or an 
engine that has been exposed to 
thermal heat for a long period of 
time.
Move choke to the "No Choke"
po si tion.
Choke lever in the "No Choke" 
position.
Move choke to the "Choke"
po si tion.
Engine switch in OFF 
po si tion.
Place engine switch in ON 
position.
No or low
pressure 
(initial use)
Spray wand not in high pressure.
See How to Use Spray Wand 
instructions in the Operation 
Section.
Low water supply.
Water supply must be at least 
5 GPM @ 20 PSI.
Leak at high pressure hose fitting.
Repair leak. Apply sealant tape
if necessary.
Nozzle obstructed.
See Nozzle Cleaning instructions 
in the Maintenance section.
Water filter screen clogged.
Remove and clean filter.
Air in hose.
Turn off the engine, then the 
water source. Disconnect the 
water source from the pump inlet 
and turn the water source on 
to remove all air from the hose. 
When there is a steady stream 
of water present, turn water 
source off. Re- con nect water 
source to pump inlet and turn on 
wa ter source. Squeeze trigger to 
re move re main ing air
High pressure hose is too long.
Use high pressure hose under
100 feet.
Choke in the “Choke” position.
Move choke to the “No Choke”
po si tion.