Lochinvar 454 1 Dépliant

Pagina di 2
Lochinvar first introduced Copper-Fin technology to the boiler 
industry some 50 years ago.  Since then, we’ve continued to refine 
and perfect it - adding advanced fan-assisted combustion, hot
surface ignition, a unique gasketless cop per finned tube heat
ex chang er and highly efficient insulating materials.
Installation Flexibility and Cost-Savings
With compact sizes that use less floor space than ever before,
all Copper-Fin units are narrow enough to fit through a standard 
36” doorway – an ad van tage most commercial boilers can’t provide. 
Plus, thanks to special insulating materials, Copper-Fin units require 
only 3” clearance from combustible walls.  What’s more, our
Stack Frame allows you to install two units in the area 
normally required for one.  This makes it easier to fit multiple 
Copper-Fin boilers into cramped me chan i cal rooms.  And you
can even use a smaller diameter vent stack - up to 8” smaller than 
typically required for comparable atmospheric boilers - so it saves 
money as well as valuable mechanical  room space.
Unique Copper-Fin Heat Ex chang er
The Lochinvar Copper-Fin boiler design uses a two 
pass heat ex chang er.  Water is circulated through 
a row of high ly-efficient, finned copper tubes.  
The high rate of water flow creates a 
scour ing action that prevents sed i ment 
and lime-scale buildup, common 
in conventional boilers, and  
the finned copper tubes 
allow maximum heat 
transfer efficiency.
To create this special 
heat transfer capability, 
Lochinvar extrudes the fins 
from thick wall copper tubing to 
precise specifications - ex act ly 7 fins per inch. 
The result is an integrally-finned tube with a heat transfer ratio 9 
times greater than a plain copper tube.
Heavy-Duty Gasketless Design
What’s more, advanced casting processes allowed Lochinvar to 
develop a unique one-piece header system.  This gasketless design 
provides enhanced reliability, improved durability and optimum 
performance - without the problems or failures common with 
O-rings and gaskets.  
Meets the Toughest Air Quality Standards
Because of our unique fan-assisted combustion 
process, the Copper-Fin exceeds today’s toughest 
NOx emissions requirements. An independent 
certification laboratory test gave us a rating of 
less than 20 ppm - corrected to 3% O
2
. And less 
NOx means a cleaner environment.
Energy Efficient, Cost Effective Boilers
Copper-Fin
®
Commercial Gas
Boilers
Enhanced to Provide Performance and Serviceability
Our enhanced Copper-Fin models offer the same reliable operation, and 
feature a more service friendly design.  The down stream test valves and 
referenced gas valves are now in the upper deck for easier access, and 
the electrical and BMS connections have been repositioned to the front 
of the unit for easier installation. 
The gas valves, which are referenced to the sealed combustion chamber, 
improve operational performance by monitoring the pressure in the 
sealed combustion chamber and adjusting gas flow to maintain the 
optimum air/fuel mixture.  And the built-in air inlet filter reduces 
maintenance and improves performance by trapping dust and airborne 
particulates that can foul the burners and blowers.  With  dual sight 
glasses (one on each end), you can easily monitor burner performance 
and flame characteristics throughout the entire combustion chamber.
The operator interface panel provides two-stage electronic 
temperature control and comprehensive diagnostic status 
without opening the control panel. Its user friendly design 
simplifies service while providing additional diagnostic 
information through a series of LEDs.
Vent Cost-Savings
 Btu/hr 
CONVENTIONAL  COPPER-FIN 
  INPUT 
VENT SIZE 
VENT SIZE 
$ SAVINGS*
 495,000 
10” 
6” 
382
 645,000 
12” 
8” 
504
 745,000 
14” 
8” 
829
 985,000 
16” 
10” 
1,228
 1,225,000 
16” 
12” 
992
 1,435,000 
18” 
12” 
1,466
 1,795,000 
20” 
14” 
1,564
 2,065,000 
22” 
14” 
2,398
 
*Comparison based on 25´ vent system using Type “B” double wall vent material, 