Alto-Shaam rotisserie electric with ventless hood Manuale Utente

Pagina di 48
MN-28907 (Rev 0) • AR-7EVH Electric Rotisserie with Ventless Hood Operation & Care Manual • 3
I N S T A L L A T I O N
In order to maintain established 
National Sanitation Foundation 
standards, all counter- mounted 
models must be sealed to the 
counter with a R.T.V. or silastic 
meeting N.S.F. requirements or 
have 6" (152mm) unobstructed 
clearance at the back and sides 
of the unit. 
1. The appliance must be 
installed in a well ventilated 
room obeying the local ventilation codes and 
standards and on a non-combustible, level surface.
2. DO NOT install this appliance in any area where it 
may be affected by any adverse conditions such as 
steam, grease, dripping water, high temperatures, or 
any other severely adverse conditions.
3.
 
For both safety and convenience, the rotisserie must 
be installed in a location to provide easy access 
to the controls and should be positioned at a safe 
and convenient height to provide easy loading and 
unloading of hot products.
4. This appliance must be kept free and clear  
of any obstructions blocking access for 
maintenance or service.
5. The AR-7EVH can be stacked on top of a matching 
holding cabinet. Complete stacking instructions are 
located in this manual.
®
LEVELING
Level the appliance from side-to-side 
and front-to-back with the use of a spirit level.  
We recommend checking the level periodically 
to make certain the floor has not shifted nor the 
appliance moved.
NOTE: 
  Failure to properly level this appliance 
can cause improper function.
MINIMUM CLEARANCE REQUIREMENTS
A 6" (152mm) minimum clearance must be allowed at the 
back and both sides of the unit. Warranty will become 
null and void if these directions are not followed.
SOUND PRESSURE MEASUREMENT
Microphone 
position
Sound pressure level dBA
Without hood 
system operating
With hood system 
operating
Front
69
71
Right Side
64.3
67
Left Side
64.3
69
Rear
64.7
68
S I T E   I N S T A L L A T I O N 
D A N G E R
IMPROPER INSTALLATION, 
ALTERATION, ADJUSTMENT, 
SERVICE, OR MAINTENANCE COULD 
RESULT IN SEVERE INJURY, DEATH, 
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION, 
OPERATING AND MAINTENANCE 
INSTRUCTIONS THOROUGHLY 
BEFORE INSTALLING OR SERVICING 
THIS EQUIPMENT.
    D A N G E R
DO NOT store or use gasoline or other 
fl ammable vapors or liquids in the 
vicinity of this or any other appliance.
C A U T I O N
METAL PARTS OF THIS EQUIPMENT 
BECOME EXTREMELY HOT WHEN 
IN OPERATION.  TO AVOID BURNS, 
ALWAYS USE HAND PROTECTION 
WHEN OPERATING THIS APPLIANCE.
C A U T I O N
TO PREVENT PERSONAL INJURY, 
USE CAUTION WHEN MOVING OR 
LEVELING THIS APPLIANCE.
A number of adjustments are associated with initial 
installation and start-up.  It is important that these 
adjustments be conducted by a qualified service 
technician.  Installation and start-up adjustments 
are the responsibility of the dealer or user.  These 
adjustments include but are not limited to thermostat 
calibration, door adjustment, leveling, electrical 
hook-up and installation of optional casters or legs.