TABLE OF CHARACTERISTICS
 
Dimensions
 
width 43.5 cm 
height 32 cm 
depth 40 cm
 
Volume
 
56 l
 
Dimensions *
 
width 43.5 cm 
height 32 cm 
depth 41.5 cm
 
Volume *
 
58 l
 
Electrical 
connections
 
voltage: 220 - 240 V~ 50/60Hz 
maximum power absorbed 2800 W 
(see data plate)
 
ENERGY 
LABEL
 
Directive 2002/40/EC on the label of 
electric ovens. Standard EN 50304 
 
Energy consumption for Natural 
convection – heating mode: 
Traditional mode
 
 
Declared energy consumption for 
Forced convection Class – heating 
mode:        Baking
 
 
This appliance conforms to the 
following European Economic 
Community directives: 2006/95/EEC 
dated 12/12/06 (Low Voltage) and 
subsequent amendments – 
2004/108/EEC dated 15/12/04 
(Electromagnetic Compatibility) and 
subsequent amendments - 
93/68/EEC dated 22/07/93 and 
subsequent amendments. 
2002/96/EC and subsequent 
amendments. 
1275/2008 stand-by/off mode 
* With glass panel fitted to the inside of the door 
Electrical Connection
Electrical connection
The electrical connection to the mains must be made
on the appliance.  The power voltage and frequency
are as indicated on the rating plate.
!  THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
• Using a screwdriver, press on the tabs situated
on each side of the terminal board cover.
• Pull open the terminal board cover.
To connect the power supply cable, proceed as
follows:
••••• Unscrew the cable clamp screw and the contact
screws L-N-6.
• Fasten the wires beneath the screwheads using
the following colour scheme: Blue (N) Brown (L)
Yellow-Green
      6
• Fasten the power supply cable in the
corresponding cable clamp and close the cover.
Electrical Connection:
Voltage Frequency: 230
V-1+N  50Hz
Fuse Section: 16A
Supply cable:
3x1.5mm
2
You can connect your oven to the system means of
a terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker
 - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of
its recess in the event of maintenance operations
(only use HAR - H 05 - RRF quality cables fitted with
a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly dangerous.
! After connecting the appliance to the flexible
cable, tighten all the screws on the terminal
board.
4
2
N
L