Lightolier MPA2G36LP3FT Dépliant

Pagina di 2
MOUNTING METHODS
DIMENSIONS
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional
T-grid ceiling (see options for 
splay trim).
drywall kit. (See options)
1/4" max.
15/16"
or 1"
24"
24"
1/4" max.
3/8"
24"
Type “G”
Fixture
15/16"
Ceiling Opening
24-5/16" x 24-5/16"
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
13/16"
Plaster Opening
24-1/8"
24-11/16"
1-1/8"  min.
3-3/4"  max.
9/16"
24"
1-1/2"  max.
1-7/8"  max.
1-7/8" max.
1-1/8"  min.
3-3/4"  max.
23 7/8"
(606mm)
15 11/16"
(398mm)
5"
(127mm)
Air supply slots
(MPA only)
2"x 2 1/2" access plate
with two K.O.s (7/8" dia.)
24" (610mm)
5" (127mm)
24" (610mm)
5" (127mm)
PARABAFFLE plus
MPA2G36LP3FT
Page 1 of 2
2'x2' RECESSED FLUORESCENT, 1 1/2" DEEP, 36 CELL PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, 2 OR 3 LAMP, TWIN TUBE T5
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
SECTION 2/Folio G20-12
FEATURES
• 5" deep body.
• 3 1/2" x 3 1/2" cell size.
• 62.9% efficient.
• Clean contoured interior.
• Eyeleted heat removal vents in fixture ends.
• One-piece housing has ribbed construction for added strength.
• Hemmed over side rails for safe handling.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips (patent no. 5,072,344).
• Pre-anodized aluminum parabolic louver.
• Vertical grain louver eliminates reflected lamp images on cross baffle.
• Spring-loaded rooster head latches.
• 18 gauge steel hinges.
• Louver frame with integral positive light stop.
• Louver has protective film dust guard.
• Construction to meet Chicago Plenum is available.