YEARLY MAINTENANCE 
Exhaust Blower Cleaning 
Although the exhaust blower and blower housing were designed to minimize ash 
build-up, some fly-ash will still accumulate there throughout the burning season.  
The amount and type of ash will depend on the type of pellets and venting system, 
but generally this accumulation will be mild.  If, when cleaning the exhaust 
blower, a large accumulation of fly-ash is found, cleaning the exhaust blower and 
housing should be performed monthly or bimonthly to prevent this excess buildup. 
Instructions 
•  Before beginning the exhaust blower cleaning procedure, be certain the unit 
is unplugged and thoroughly cooled down. 
•  Loosen, but do not remove, the three 5/16” screws on the rear of the unit, on 
the side nearest the exhaust blower (the left side when facing the front of the 
stove). 
•  The side panel is held to the front of the stove by two key slot supports; 
gently pull the back end of the side panel away from the stove until the head 
of the screw is in the center of the square cutout on the back of the side 
panel. 
•  Pull the side panel straight back, supporting it carefully, and when it cannot 
be pulled back any further, pull it away from the stove; the side panel should 
slip off of the key slot supports (See diagram pg. 33) 
•  Once the side panel is removed, the exhaust blower will be clearly visible. 
•  Disconnect the venting system from the exhaust blower just enough that you 
will be able to remove the exhaust blower from the stove. 
•  Unplug the two wires which connect the stove wiring harness to the exhaust 
blower using the quick connect plugs. 
•  Loosen and remove the 5/16” screw, on the top of the exhaust blower output 
connection, which holds the thermal sensor to the exhaust blower.