18954-0-0705
This is an unvented gas-fired heater. It uses air (oxygen) from the 
room in which it is installed. Provisions for adequate combustion 
and ventilation air must be provided.
Keep  room  area  clear  and  free  from  combustible  materials, 
gasoline and other flammable vapors and liquids.
Unvented gas heaters are a supplemental zone heater. They are not 
intended to be a primary heating appliance. Water vapor produced 
by an unvented heater can create moisture problems in a home 
when operated for extended periods of time.
During  manufacturing,  fabricating  and  shipping,  various 
components of this appliance are treated with certain oils, films or 
bonding agents. These chemicals are not harmful but may produce 
annoying smoke and smells as they are burned off during the initial 
operation of the appliance; possibly causing headaches or eye or 
lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner 
at the highest setting. Provide maximum ventilation by opening 
windows or doors to allow odors to dissipate. Any odors remaining 
after this initial break-in period will be slight and will disappear 
with continued use.
This appliance must not be used with glass doors in the closed 
position. This can lead to pilot outages and severe sooting outside 
the fireplace.
Do not use this room heater if any part has been under water. 
Immediately  call  a  qualified  service  technician  to  inspect  the 
room heater and replace any part of the control system and any 
gas control which has been under water.
WARNING: This appliance is equipped for (natural or propane) 
gas. Field conversion is not permitted.
Before you get started
Carefully inspect the contents for shipping damage. If any parts are 
missing or damaged, immediately inform the dealer from whom 
you purchased the appliance. Do not attempt to install any part of 
the appliance unless you have all parts in good condition.
Make sure you have received all parts:
Check your packing list to verify that all listed parts have been 
received. You should have the following:
•  Gas log grate/burner assembly.
•  Two (2) masonry anchoring screws and two (2) 10 x 1/2" black 
sheet metal anchoring screws.
•  Plastic bag containing glowing embers (rock wool) for burner 
coverage.
•  Plastic bag containing lava rock.
•  Switch log assembly - VFSR models
•  Remote kit - VFSV models
Millivolt controlled heater designed to be operated with optional 
devices for ON/OFF functions.
•  Wall switch or thermostat with wire.
•  Hand  held  remote  control  with  ON/OFF  switch  or 
thermostat.
Handle the gas log burner assembly by the grate and legs only. 
Do not pick the unit up by the burner.
Gloves are recommended when handling logs to prevent skin 
irritation. Logs are fragile - Handle with care.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall 
be  performed  only  by  a  qualified  agency. The  term  "qualified 
agency"  means  any  individual,  firm,  corporation,  or  company 
that either in person or through a representative is engaged in and 
is responsible for (a) the installation, testing, or replacement of 
gas piping or (b) the connection, installation, testing, repair, or 
servicing of equipment; that is experienced in such work; that is 
familiar with all precautions required, and that has complied with 
all the requirements of the authority having jurisdiction.
State  of  Massachusetts: The  installation  must  be  made  by 
a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental 
room heaters shall provide to each purchaser a copy of 527 
CMR-30 upon sale of the unit.
The installation must conform with local codes or, in the absence of 
local codes, with the National Fuel Gas Code, ANSI Z223.1.*
*Available from the American National Standards Institute, Inc. 11 West 42nd 
St., New York, N.Y. 10018.
High Altitudes: For altitudes/elevation above 2,000 feet ratings 
should be reduced at the rate of 4 percent for each 1,000 feet above 
sea level. Contact the manufacturer.
BRUCE SPECIAL COPY
GENERAL INFORMATION
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An unvented room 
heater produces approximately one (1) ounce (30ml) of water for 
every 1,000 BTU's (.3KW's) of gas input per hour. 
Unvented room heaters must be used as supplemental heat (a 
room) rather than a primary heat source (an entire house). In most 
supplemental heat applications, the water vapor does not create a 
problem. In most applications, the water vapor enhances the low 
humidity atmosphere experienced during cold weather. 
 The following steps will help insure that water vapor does not 
become a problem.  
1.  Be sure the heater is sized properly for the application, including 
ample combustion air and circulation air.
2.  If high humidity is experienced, a dehumidifier may be used 
to help lower the water vapor content of the air.
3.  Do not use an unvented room heater as the primary heat source 
(an entire house).