E. Float Switch
Depending on local water conditions, scale may build up on the float switch. Scale on the 
switch can cause the floats to stick. In this case, the float switch should be cleaned and 
checked.
First, remove the switch from the water tank. Soak the switch assembly in ice machine
cleaner. While not necessary, the floats can be removed from the shaft during cleaning. 
If you remove them, note that the blue float is on top. The floats must be installed with 
the magnets inside them towards the top of the switch. Installing the floats upside down 
will affect the timing of the float switch operation. Once clean, rinse and wipe the cleaner 
off. Next, check the switch with an ohm meter. This float switch has three wires (the 
black wire is common) and two separate switches. Check the upper switch by ohming 
out the black and red wires. When the float is up, the switch should be closed. Check the 
lower switch by ohming out the black and blue wires in the same manner. If either switch 
fails, the assembly should be replaced.
Red (upper)
Black (common)
Blue (lower)
Upper Float (blue)
Magnet (towards top)
Magnet (towards top)
Lower Float (white)
Plastic Retainer Clip
Spring Retainer Clip