Hoshizaki DCM-750BWH(-OS) Manuale Supplementare

Pagina di 69
3
7. High Pressure Switch 
When the high pressure switch opens, the compressor stops immediately, 60 seconds 
later the gear motor stops. To restart, allow time for the high pressure switch to close, 
then move the power switch to the "OFF" position and then back to the "ON" position.
BK
BLACK
O
ORANGE
W/BK WHITE/BLACK
BR
BROWN
P
PINK
W/BR WHITE/BROWN
BU
BLUE
R
RED
W/BU WHITE/BLUE
DBU DARK BLUE
V
VIOLET
W/O WHITE/ORANGE
GY
GRAY
W
WHITE
W/R WHITE/RED
LBU LIGHT BLUE
Y
YELLOW
WIRE COLOR CODE
DCM-750BAH-OS, 
DCM-750BWH-OS
DCM-750BAH, 